2014
DOI: 10.1021/ac5002228
|View full text |Cite
|
Sign up to set email alerts
|

Direct Determination of Dissolved Phosphate and Silicate in Seawater by Ion Exclusion Chromatography Sector Field Inductively Coupled Plasma Mass Spectrometry

Abstract: Access and use of this website and the material on it are subject to the Terms and Conditions set forth at Direct determination of dissolved phosphate and silicate in seawater by ion exclusion chromatography sector field inductively coupled plasma mass spectrometry Yang, L.; Pagliano, E.; Mester, Z. NRC Publications Record / Notice d'Archives des publications de CNRC:http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/ctrl?action=rtdoc&an=21272119&lang=en http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/ctrl?action=rtdo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
17
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 34 publications
1
17
0
Order By: Relevance
“…The concentration of dissolved phosphate determined in sea-water with this ion chromatographic method (1.69 ± 0.04) µmol/L is in good agreement with the result of the colorimetric procedure (1.71 ± 0.04) µmol/L [38]. Typical chromatogram of a sample is in the original publication presented in Figure 4. …”
Section: Phosphatesupporting
confidence: 79%
“…The concentration of dissolved phosphate determined in sea-water with this ion chromatographic method (1.69 ± 0.04) µmol/L is in good agreement with the result of the colorimetric procedure (1.71 ± 0.04) µmol/L [38]. Typical chromatogram of a sample is in the original publication presented in Figure 4. …”
Section: Phosphatesupporting
confidence: 79%
“…An ion-exclusion chromatography (IEC) isotope dilution inductively coupled plasma sector field mass spectrometry (IEC-ID-ICP-MS) was developed in previous studies. 5,6 It is recognized to be one of the primary methods of measurement. 7 Although it is able to give sufficient accuracy for the measurement, in some cases it is difficult to use it because it required complicated operations, such as isotope dilution and expensive apparatus, such as an ICP-sector field mass spectrometer.…”
Section: Introductionmentioning
confidence: 99%
“…Usually poorer precision of final results is expected due to the larger uncertainty associated with linear regression of intensities used for the quantitation. Alternatively, combining the standard addition and internal standardization may significantly improve analytical precision through the correction of drifts during analysis 2023 . In order to provide a second set of high quality data for Ca, K, Mg and Na for the certification of AQUA-1 drinking water CRM, complementary to the ICP-AES results, Mg was measured using double ID.…”
Section: Resultsmentioning
confidence: 99%