1990
DOI: 10.1063/1.345326
|View full text |Cite
|
Sign up to set email alerts
|

Direct determination of absolute monolayer coverages of chemisorbed C2H2 and C2H4 on Si(100)

Abstract: A convenient kinetic uptake method has been employed to determine the absolute saturation monolayer coverage of C2H2 and C2H4 on a Si(100)(2×1) surface. Such measurements are important for postulating the structure of the chemisorbed hydrocarbon species on this surface. The saturation surface coverage for both chemisorbed molecules at 105 K is 2.5(±0.2)×1014 molecules/cm2 . This number is consistent with 1 hydrocarbon molecule per Si dimer site at monolayer coverage when the role of surface defects on Si(100) … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

4
67
0

Year Published

1993
1993
2020
2020

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 150 publications
(71 citation statements)
references
References 20 publications
4
67
0
Order By: Relevance
“…The ultrahigh vacuum (UHV) system (with a base pressure of 1 x 10-10 Torr) and the Si(100) crystal preparation have been described previously [12][13][14][15][16]; selected aspects will be summarized here. The system is equipped with an Auger electron spectrometer, an argon ion sputtering gun, a collimated and calibrated microcapillary array doser [21], and a multiplexed quadrupole mass spectrometer (QMS) with capabilities for both random flux and line-of-sight detection (22].…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The ultrahigh vacuum (UHV) system (with a base pressure of 1 x 10-10 Torr) and the Si(100) crystal preparation have been described previously [12][13][14][15][16]; selected aspects will be summarized here. The system is equipped with an Auger electron spectrometer, an argon ion sputtering gun, a collimated and calibrated microcapillary array doser [21], and a multiplexed quadrupole mass spectrometer (QMS) with capabilities for both random flux and line-of-sight detection (22].…”
Section: Methodsmentioning
confidence: 99%
“…Heating of the For the adsorption of molecular species, a calibrated microcapillary array doser was used to deliver the gas molecules onto the Si(100) surface [21]. The doser contains an internal pinhole aperture (2 Am diameter) whose conductance has been calibrated accurately for the molecular species to be studied [12]. The partial pressure change of the molecular onto the crystal surface is determined from the calibrated conductance through the internal pinhole aperture [12] and from the calculated angular distribution of the beam [24].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, an ultraviolet photoemission spectroscopy study with the kinetic uptake method determined the saturation coverage to be ϭ1 ML. [14][15][16] In this work we study the adsorption of both C 2 H 2 and C 2 H 4 molecules on Si͑100͒ for coverages of ϭ0.5 and 1 ML, using the same first-principles calculation scheme. 17,18 Here the equilibrium geometries and energetics of the three existing models, i.e., dimerized, dimer-cleaved, and tetramodels, are considered.…”
mentioning
confidence: 99%