1996
DOI: 10.6028/nist.tn.1379
|View full text |Cite
|
Sign up to set email alerts
|

Direct comparison transfer of microwave power sensor calibrations

Abstract: This report describes a basic, but potentially accurate, transfer technique for comparing microwave power sensors. The technique is not new, but the specific applications are.This report is written to supplement the existing literature. The method transfers the effective efficiency of a standard power sensor to an unknown (uncalibrated) power sensor. The power sensors may be bolometric (thermistor mounts), thermoelectric, or diode types, and each type will have inherent limitations. The technique can be implem… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
27
0
1

Year Published

2011
2011
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(31 citation statements)
references
References 6 publications
(23 reference statements)
0
27
0
1
Order By: Relevance
“…Its performance was evaluated by the GUM and the MCM. The observed good agreements (all the |E n | ≤ 0.25) demonstrate the capability of the calibration model in (1). However, to be a reliable model for providing the calibration services to the industry, calibration scenarios using other adaptors (e.g., female to male adaptor, coaxial to waveguide adaptor etc.)…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Its performance was evaluated by the GUM and the MCM. The observed good agreements (all the |E n | ≤ 0.25) demonstrate the capability of the calibration model in (1). However, to be a reliable model for providing the calibration services to the industry, calibration scenarios using other adaptors (e.g., female to male adaptor, coaxial to waveguide adaptor etc.)…”
Section: Discussionmentioning
confidence: 99%
“…Direct comparison transfer technique has been widely used for microwave power sensor calibrations [1][2][3][4] since it was proposed by the National Institute of Standards and Technology, USA [1]. This technique, as shown in Figure 1(a), consists of a power source (microwave synthesizer) and a 3-port splitter or coupler which is used to minimize the source mismatch [5].…”
Section: Introductionmentioning
confidence: 99%
“…The expanded uncertainty discussed in this study is reasonably relaxed to increase reliability, and the resultant uncertainty is posted as the calibration and measurement capabilities on the International Bureau of Weights and Measures webpage [10]. The RF and microwave power standards discussed in this study are disseminated to domestic and foreign users by the direct comparison technique [11]. These standards ultimately help users to measure the related quantities with reliability.…”
Section: Measurements and Resultsmentioning
confidence: 99%
“…Also best accuracy is usually provided by thermistor type detectors at these frequencies [2]. By including thermistor as one arm of a 4-arm balanced bridge, DC or low-frequency AC power is drawn as RF/ MW/ MMW power is applied, maintaining the bridge balance and yielding a substitution value of power [3]. Recently, signal & sweep generators, scalar & vector network analyzers, thermistor mounts and direct reading attenuators, etc.…”
mentioning
confidence: 99%