1999
DOI: 10.1053/hj.1999.v137.92779
|View full text |Cite
|
Sign up to set email alerts
|

Direct comparison of early elevations of cardiac troponin T and I in patients with clinical unstable angina

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

1999
1999
2011
2011

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(10 citation statements)
references
References 24 publications
0
10
0
Order By: Relevance
“…Serum cTnI was measured on a number of assay platforms; six trials utilised the Stratus II analyzer (Dade Behring, Miami, Fla., USA) [5, 8, 10, 13, 16, 21], five the Opus Magnum (Dade Behring, Westwood, Mass., USA) [7, 9, 12, 14, 18]and one each the ACCESS (Beckman, Chaska, Minn., USA) [15]and the AxSYM (Abbott Diagnostics, Abbott Park, Ill., USA) [6]assay systems. Concordance between values obtained when a given patient sample is assayed on different platforms is low, and results may vary up to 20-fold [26].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Serum cTnI was measured on a number of assay platforms; six trials utilised the Stratus II analyzer (Dade Behring, Miami, Fla., USA) [5, 8, 10, 13, 16, 21], five the Opus Magnum (Dade Behring, Westwood, Mass., USA) [7, 9, 12, 14, 18]and one each the ACCESS (Beckman, Chaska, Minn., USA) [15]and the AxSYM (Abbott Diagnostics, Abbott Park, Ill., USA) [6]assay systems. Concordance between values obtained when a given patient sample is assayed on different platforms is low, and results may vary up to 20-fold [26].…”
Section: Methodsmentioning
confidence: 99%
“…The population upper limit of normal is in the case of each assay several standard deviations below the pathologic cut-off point. As regards the trials in our meta-analysis six [5, 8, 10, 12, 14, 21]utilised a cut-off point value approximating the upper limit of normal for the given assay, whereas the remaining 7 trials used the pathologic cut-off point.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Direct comparison of early elevations of troponin T and troponin I in patients with unstable angina indicate that both markers identify myocardial damage in equal numbers of patients [23].…”
Section: Troponins As Markers Of 'High Risk'mentioning
confidence: 99%
“…Laboratory data no longer simply confirm or negate previously obtained clinical data, but are an integral part of patient management. There is a considerable body of evidence demonstrating the important role of clinical laboratories in disease management, the most frequently cited examples being the measurement of glycated hemoglobin in diabetes (10), C-reactive protein in infectious diseases (11), and cardiac troponins in acute coronary syndrome (12,13). It has already been demonstrated that laboratory tests are effective not only in improving medical outcome (the primary goal), but also in reducing hospital stay length and total costs (14,15).…”
Section: Clinical-laboratory Relationshipsmentioning
confidence: 99%