2006
DOI: 10.1016/j.sna.2006.03.022
|View full text |Cite
|
Sign up to set email alerts
|

Digital sensors design based on universal frequency sensors interfacing IC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 11 publications
0
11
0
Order By: Relevance
“…In PBS, the two-sample Allan variance for the oscillator has been calculated to be 3 × 10 −7 which is comparable to the results reported for a 2 MHz oscillator in water by Rodriguez-Pardo et al [9] although our value is greater than they report for a 9 MHz QCM. A UFDC-1 universal frequency to digital converter [10] was used as a low-cost replacement for the Agilent frequency counter. The UFDC-1 is a 28 pin single-chip programmable two-channel frequency-todigital converter, operating over the frequency range 0.05 Hz to 7.5 MHz; this range can be extended to 120 MHz with prescaling although this results in an accuracy reduction.…”
Section: Methodsmentioning
confidence: 99%
“…In PBS, the two-sample Allan variance for the oscillator has been calculated to be 3 × 10 −7 which is comparable to the results reported for a 2 MHz oscillator in water by Rodriguez-Pardo et al [9] although our value is greater than they report for a 9 MHz QCM. A UFDC-1 universal frequency to digital converter [10] was used as a low-cost replacement for the Agilent frequency counter. The UFDC-1 is a 28 pin single-chip programmable two-channel frequency-todigital converter, operating over the frequency range 0.05 Hz to 7.5 MHz; this range can be extended to 120 MHz with prescaling although this results in an accuracy reduction.…”
Section: Methodsmentioning
confidence: 99%
“…(1) It contains a tightly coupled with the ground coccygeal vertebra (1), MEMS acceleration detector chip(2), the output line (4) and connect the chip and the coccygeal vertebra close shell (3).In seismic exploration, the seismic wave with different stratum reflection to the surface of the ground coupled coccygeal vertebra in the form of vibration signal to MEMS acceleration detector chip [4].As shown in fig2, when the vibration signal reaches the detector chip, quality body (a) the displacement controlled by displacement detector (c) perceive and adjust the electromotive force feedback capacitance change (b), make its produce a balancing force, force quality body keep zero position [1].Capacitance variation depends on the strength of vibration signal and electromotive force variation depends on the capacitance variation, therefore, the change of the electromotive force curve on real-time tracking vibration signal intensity change curve, this is the working principle of the MEMS acceleration detector. It is can be seen that detector chip system is mainly composed of three parts: MEMS sensor acquisition module, A/D conversion module and the signal processing module cache.…”
Section: The Working Principle Of Detectormentioning
confidence: 99%
“…In [10], [11], the author proposes to renounce to the standard AD conversion and suggests, as a new IEEE standard, the use of low-complexity low-power architecture based on quasidigital output signals to encode analog quantities. The technique achieves good results both for low resistance [12] and high resistance [13] read-out.…”
Section: Fast Zno-nws Assembling Onto M4n Chipmentioning
confidence: 99%