2015
DOI: 10.1016/j.jcrs.2014.05.049
|View full text |Cite
|
Sign up to set email alerts
|

Digital pupillometry and centroid shift changes after cataract surgery

Abstract: Dr. Kanellopoulos is a consultant to Alcon Surgical, Inc., Wavelight Laser Technologie AG, Allergan, Avedro, Inc., and i-Optics Corp. No author has a financial or proprietary interest in any material or method mentioned.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
14
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 21 publications
(19 citation statements)
references
References 35 publications
3
14
0
2
Order By: Relevance
“…Pentacam HR (-9.42%). Our results corroborate the findings obtained by Kanellopoulos et al, 32 showing a reduction of the µ-chord from 0.12 to 0.05 mm (50%) and a photopic and mesopic pupil diameter reduction of -9.8% and -9.1%, respectively, after cataract surgery.…”
Section: Discussionsupporting
confidence: 93%
See 1 more Smart Citation
“…Pentacam HR (-9.42%). Our results corroborate the findings obtained by Kanellopoulos et al, 32 showing a reduction of the µ-chord from 0.12 to 0.05 mm (50%) and a photopic and mesopic pupil diameter reduction of -9.8% and -9.1%, respectively, after cataract surgery.…”
Section: Discussionsupporting
confidence: 93%
“…The correlation between pupil change of Pentacam and difference in µ-chord after surgery suggest that the variation in µ-chord is mainly due to the variation of pupil center position with pupil diameter change as it has been previously reported. 32 The µ-chord, which is correlated with kappa angle, 26,33 has been hypothesized to be related with the visual performance achieved with MIOLs. 34 However, to this date, there is only one clinical study that correlates the kappa angle with the visual performance.…”
Section: Discussionmentioning
confidence: 99%
“…That is, pupil size was not taken into account in this study. Cataract extraction surgery is known to affect pupil size and centration [ 28 , 29 ]. However, none of our patients had any pupillary abnormalities and their pupils were within the normal size range after the cataract surgery.…”
Section: Discussionmentioning
confidence: 99%
“…Multifocal IOLs with concentric refractive ring design may benefit from a central zone that is smaller than the photopic pupil diameter (32). In many cases, the postoperative pupil is significantly smaller than the preoperative pupil (33,34). The preoperative pupil size has limited ability to assist the choice of well-suited refractive multifocal or aspheric IOLs.…”
Section: Discussionmentioning
confidence: 99%