2008 IEEE Instrumentation and Measurement Technology Conference 2008
DOI: 10.1109/imtc.2008.4547287
|View full text |Cite
|
Sign up to set email alerts
|

Digital Pulse Volume Based Endothelial Function Detector for Early Stage Formation of Atherosclerosis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2009
2009
2017
2017

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 10 publications
0
7
0
Order By: Relevance
“…Peripheral microvascular endothelial function assessment has been proven to be effective in the RH-PAT studies; previous study [15][16][17] also proposed a method that assesses endothelial function by observing the change of waveform after the stimulation as well, that is, the PPG system. The PPG system uses an infrared sensor on the left index finger's microvascular bed; it extracts numerous digital volume pulse waveform to serve as a baseline (Area Basline ), then a pressure cuff is used on the left upper arm for occlusion for 4 min; this will cause endothelium cells to react and produce NO for vasodilatation.…”
Section: Vaso-dilatation Index For Ppg Systemmentioning
confidence: 99%
See 3 more Smart Citations
“…Peripheral microvascular endothelial function assessment has been proven to be effective in the RH-PAT studies; previous study [15][16][17] also proposed a method that assesses endothelial function by observing the change of waveform after the stimulation as well, that is, the PPG system. The PPG system uses an infrared sensor on the left index finger's microvascular bed; it extracts numerous digital volume pulse waveform to serve as a baseline (Area Basline ), then a pressure cuff is used on the left upper arm for occlusion for 4 min; this will cause endothelium cells to react and produce NO for vasodilatation.…”
Section: Vaso-dilatation Index For Ppg Systemmentioning
confidence: 99%
“…More importantly, peripheral arteries can adjust the blood flow automatically. In that way, the wave signals [15,16] from the PPG system's sensors will not reflect the vasodilatation index exactly. That is the reason why we used the proposed air pressure sensing system in this study.…”
Section: Vaso-dilatation Index For Ppg Systemmentioning
confidence: 99%
See 2 more Smart Citations
“…Rather it uses tonometry to sense the change of amplitude of arterial waveforms for assessing endothelial function. The correlation between coronary and peripheral microvascular endothelial function is well established, and in previous studies, using Photoplethysmography (PPG) [8] to calculate the area under the curve of the waveform for assessing the function of endothelium cell has been proven to be highly correlated with the traditional RH-PAT method. The area under the curve of finger digital volume pulse grossly represents the volume change of blood flow into this finger during each pulse [9].…”
Section: Introductionmentioning
confidence: 99%