1971
DOI: 10.1021/ac60306a025
|View full text |Cite
|
Sign up to set email alerts
|

Digital potentiostat

Abstract: A Digital PotentiostatSir: Reported, for the first time, is an instrument for potentiostatic control of an electrochemical cell employing a new technique-digital current feedback. Digital current pulses, which can be scaled to read-out directly on a scaler the

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

1973
1973
2021
2021

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 2 publications
0
8
0
Order By: Relevance
“…With the interrupter method [36][37][38][39][40][41][42][43][44][45][46][47][48] the polarization current is interrupted periodically for short times within the microsecond range. In these interrupter periods t 0 the ohmic voltage drop iR u disappears immediately, while the "true" polarization voltage E p of the working electrode only decreases slowly due to the storage capacity of the double layer C dl .…”
Section: Current Interrupt Methodsmentioning
confidence: 99%
“…With the interrupter method [36][37][38][39][40][41][42][43][44][45][46][47][48] the polarization current is interrupted periodically for short times within the microsecond range. In these interrupter periods t 0 the ohmic voltage drop iR u disappears immediately, while the "true" polarization voltage E p of the working electrode only decreases slowly due to the storage capacity of the double layer C dl .…”
Section: Current Interrupt Methodsmentioning
confidence: 99%
“…The pulsed ramp and differential amplifier were those normally used in the differential pulse polarography mode of the 174 Polarographic Analyzer. To minimize instrumental artifacts of the kind recently reported (7), time constants in the sample-and-hold circuitry were decreased by a factor of 100 compared with those supplied by the manufacturer. All measurements were made with a three-electrode system with Ag/AgCl as the reference electrode and platinum as the auxiliary electrode.…”
Section: Methodsmentioning
confidence: 99%
“…The method of potentiostatic control used in the instrument is similar in principle to that used in the "digital potentiostat" of Goldsworthy and Clem (7). However, this device generates approximately 50-fold greater average current, and the charge injection circuitry is fundamentally more precise because capacitive discharge is employed here, rather than timed current injection.…”
Section: Description Of the Coulometermentioning
confidence: 99%