1996
DOI: 10.1111/j.1600-0765.1996.tb00479.x
|View full text |Cite
|
Sign up to set email alerts
|

Digital image ratio: a new radiographic method for quantifying changes in alveolar bone. Part 1: theory and methodology

Abstract: A new world, digital image ratio (DIR), has been developed for directly measuring changes in alveolar bone. The image on the computer monitor represents the relative mass change between two radiographs. Fourier filtering is used to reduce noise artefacts. This method is validated through an experiment with a step wedge. DIR needs only a preliminary calibration of the experimental conditions of operation and avoids tedious calibrations for each measurement as in the case of digital image substraction. Low-volta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
3
0
1

Year Published

1996
1996
2007
2007

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 23 publications
1
3
0
1
Order By: Relevance
“…The contrast curve of the film is another important parameter for the evaluation of the correlation between calcium mass changes and radiographic density changes. The contrast curve is not linear, but it is close to linear in the so-called diagnostic area of the film (34). The excellent linear correlations between the mean calcium mass per pixel and the corresponding radiographic density changes, which were found for each individual jaw in the present study (Table 2a-c), are the best proof that the quasi-linear diagnostic area of the film contrast curve was not left in the present study.…”
Section: Discussion Of the Methodssupporting
confidence: 51%
“…The contrast curve of the film is another important parameter for the evaluation of the correlation between calcium mass changes and radiographic density changes. The contrast curve is not linear, but it is close to linear in the so-called diagnostic area of the film (34). The excellent linear correlations between the mean calcium mass per pixel and the corresponding radiographic density changes, which were found for each individual jaw in the present study (Table 2a-c), are the best proof that the quasi-linear diagnostic area of the film contrast curve was not left in the present study.…”
Section: Discussion Of the Methodssupporting
confidence: 51%
“…Measurements obtained from the plaster sections represented both hard and soft tissue support and could not be individualized. However, findings from other studies, using complex radiographic methodologies, would suggest that postextraction tissue loss is predominantly due to alveolar resorption (12). Indeed, inclusion of gingival contour in our analysis may have actually masked the true extent of underlying bony atrophy as, in some cases, denture‐induced gingival hyperplasia was present.…”
Section: Discussionmentioning
confidence: 99%
“…Images were stored with the TIFF format. They were treated using Triton software, [16][17][18] which runs on a number of Unix workstations. Triton is an interactive program devoted to numerical image processing mainly based on Fourier filtering and wavelet analysis.…”
Section: Texture Analysismentioning
confidence: 99%