2009
DOI: 10.1088/0022-3727/42/21/214004
|View full text |Cite
|
Sign up to set email alerts
|

Digital image correlation and fracture: an advanced technique for estimating stress intensity factors of 2D and 3D cracks

Abstract: Abstract. Digital image correlation is a measurement technique that allows one to retrieve displacement fields "separating" two digital images of the same sample at different stages of loading. Because of its remarkable sensitivity, it is not only possible to detect cracks with sub-pixel opening, which would not be visible, but also to provide accurate estimates of stress intensity factors. For this purpose suitable tools have been devised to minimize the sensitivity to noise. Working with digital images allow… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
147
0
1

Year Published

2010
2010
2018
2018

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 209 publications
(151 citation statements)
references
References 82 publications
(162 reference statements)
3
147
0
1
Order By: Relevance
“…DIC is definitely a tool of choice to analyze cracked samples and structures [2]. In particular, for cyclic tests, one key aspect is related to the estimation of crack opening and closure levels when studying the propagation conditions.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…DIC is definitely a tool of choice to analyze cracked samples and structures [2]. In particular, for cyclic tests, one key aspect is related to the estimation of crack opening and closure levels when studying the propagation conditions.…”
Section: Introductionmentioning
confidence: 99%
“…This type of approach was applied both on numerical simulations [27], and experimental results [5,28,2,26]. It will be used herein to follow the crack tip in a cyclic test during which propagation occurs.…”
Section: Introductionmentioning
confidence: 99%
“…This condition is clearly violated when a crack is formed on the specimen, and suggests additional care when dealing with DIC measurements from dynamic impact tests, such as in, e.g., [45], [47]. Thus, care must be taken to exclude regions where the continuum hypothesis is violated, unless extended DIC formulations are adopted [60], [61]. However, such extended DIC formulations are still under development, and out of the scope of the present review.…”
Section: Digital Image Correlationmentioning
confidence: 96%
“…This measurement method is simple to implement compare to others methods and the precision of the system is circa one micrometer [13]. Only the treated area was measured and is represented as follow.…”
Section: B Sample Shape Measurementmentioning