Asymptomatic Atherosclerosis 2010
DOI: 10.1007/978-1-60327-179-0_18
|View full text |Cite
|
Sign up to set email alerts
|

Digital (Fingertip) Thermal Monitoring of Vascular Function: A Novel, Noninvasive, Nonimaging Test to Improve Traditional Cardiovascular Risk Assessment and Monitoring of Response to Treatments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
1
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 23 publications
0
1
0
1
Order By: Relevance
“…Another method, called Digital Thermal Monitoring (DTM), has been developed to measures peripheral vascular reactivity using reactive hyperaemia after increasing the blood pressure (BP) to suprasystolic values. The measurements using this instrument have excellent reproducibility and low variability 25 , demonstrate strong relationship with flow mediated dilation technique (FMD) 26 , coronary calcium score, myocardial perfusion defects, and coronary angiography 10,[27][28][29][30][31][32] and were validated for detecting ED and CVD risk 1, 10, 26, 30, 33 . In addition, similarly to DVA, DTM is also a non-invasive technique that can be performed in primary care settings, therefore, suitable for early screening. However, these two instruments assess vascular beds with different anatomical properties and exposed to different physiological influences 34,35 .…”
Section: Introductionmentioning
confidence: 97%
“…Another method, called Digital Thermal Monitoring (DTM), has been developed to measures peripheral vascular reactivity using reactive hyperaemia after increasing the blood pressure (BP) to suprasystolic values. The measurements using this instrument have excellent reproducibility and low variability 25 , demonstrate strong relationship with flow mediated dilation technique (FMD) 26 , coronary calcium score, myocardial perfusion defects, and coronary angiography 10,[27][28][29][30][31][32] and were validated for detecting ED and CVD risk 1, 10, 26, 30, 33 . In addition, similarly to DVA, DTM is also a non-invasive technique that can be performed in primary care settings, therefore, suitable for early screening. However, these two instruments assess vascular beds with different anatomical properties and exposed to different physiological influences 34,35 .…”
Section: Introductionmentioning
confidence: 97%
“…Ante esta situación han surgido nuevas técnicas diagnósticas que evalúan RV mediante HR en una extremidad (5,(8)(9)(10)(11)(12)(13)(14) , las cuales buscan un promisorio avance en la detección temprana de las ECV, sin embargo estos métodos se encuentran en estado de desarrollo y requieren validación y aceptación clínica.…”
Section: Introductionunclassified