1990
DOI: 10.1080/00387019008054478
|View full text |Cite
|
Sign up to set email alerts
|

Digital Filtering of Weakly Structured UV/VIS Spectra of Inorganic Compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

1992
1992
2009
2009

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 65 publications
(13 citation statements)
references
References 11 publications
0
13
0
Order By: Relevance
“…Reflectance spectra for (1), (2) and phenytoin (L) (5000-50000 cm -1 ) were measured on a Cary 500 Scan (Varian) UV-vis-NIR spectrophotometer. To obtain accurate band positions, the spectra were analyzed using variable digital filter method [14,15] with the following parameters: a real number determining the degree of resolution enhancement, a = 200.0; the integer number determining the filter width, N = 10; the increment between points (step) = 100 cm -1 . Magnetic moments were measured using an MSB-MKI instrument (Sherwood Scientific Ltd.) at ambient temperature with Co[Hg(SCN)4] as the standard.…”
Section: Physical Measurementsmentioning
confidence: 99%
“…Reflectance spectra for (1), (2) and phenytoin (L) (5000-50000 cm -1 ) were measured on a Cary 500 Scan (Varian) UV-vis-NIR spectrophotometer. To obtain accurate band positions, the spectra were analyzed using variable digital filter method [14,15] with the following parameters: a real number determining the degree of resolution enhancement, a = 200.0; the integer number determining the filter width, N = 10; the increment between points (step) = 100 cm -1 . Magnetic moments were measured using an MSB-MKI instrument (Sherwood Scientific Ltd.) at ambient temperature with Co[Hg(SCN)4] as the standard.…”
Section: Physical Measurementsmentioning
confidence: 99%
“…The solution absorption spectra in methanol were recorded for c = 1 9 10 -3 M. The scans of all spectra were accumulated with resolution of 10 cm -1 . In order to obtain the values of the band number and positions, the variable digital filter analysis has been performed [24][25][26]. Additionally, the solution spectrum was deconvoluted into Gaussian band components [27][28][29][30].…”
Section: Physical Measurementsmentioning
confidence: 99%
“…The spectra were recorded in the following conditions: (a) diffuse-reflectance spectrum with identical parameters as a baseline of a white sample (reference); (b) absorption spectrum in formamide solution (c = 5 9 10 -3 M). In order to obtain the approximate values for the band position, the spectral analysis was performed using the variable digital filter method [15][16][17][18][19]. For exact values of the band positions, intensities (absorption spectra), and half-widths, the spectra have been deconvoluted into Gaussian components using a modification of non-linear least squares algorithm [20][21][22].…”
Section: Methodsmentioning
confidence: 99%