Digital breast tomosynthesis: Dose and image quality assessment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

1
30
1
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(33 citation statements)
references
References 30 publications
1
30
1
1
Order By: Relevance
“…Especially for digital breast tomosynthesis (DBT), many investigations determining the impact of scanning angle, dose distribution, and reconstruction filters on the MTF were carried out. Most commonly, a wire phantom containing a tungsten wire or a slanted edge is used to measure the MTF . Yet, as the proposed scanning geometry is different from the one used in DBT, where the detector usually remains static, the mentioned studies do not cover an analysis of the proposed acquisition technique.…”
Section: Introduction and Purposementioning
confidence: 99%
See 1 more Smart Citation
“…Especially for digital breast tomosynthesis (DBT), many investigations determining the impact of scanning angle, dose distribution, and reconstruction filters on the MTF were carried out. Most commonly, a wire phantom containing a tungsten wire or a slanted edge is used to measure the MTF . Yet, as the proposed scanning geometry is different from the one used in DBT, where the detector usually remains static, the mentioned studies do not cover an analysis of the proposed acquisition technique.…”
Section: Introduction and Purposementioning
confidence: 99%
“…Most commonly, a wire phantom containing a tungsten wire or a slanted edge is used to measure the MTF. [24][25][26][27][28][29][30][31] Yet, as the proposed scanning geometry is different from the one used in DBT, where the detector usually remains static, the mentioned studies do not cover an analysis of the proposed acquisition technique.…”
Section: Introduction and Purposementioning
confidence: 99%
“…Indeed, tomographic techniques like X-ray computed tomography (CT) are known to reproduce with high contrast the body or organ 3D anatomy. Digital breast tomosynthesis (DBT)-which produces pseudo-tomographic 3D images of the compressed breast with anisotropic resolution [1][2][3][4]-is routinely adopted in the clinic for second level examinations; clinical reports for its application in screening studies have been presented recently [5]. In the last few years, following the techniques and scanning strategy initially proposed by Boone et al [6] and Chen and Ning [7], cone-beam CT dedicated to the breast (BCT) [6][7][8][9][10][11][12][13] received regulatory approval in USA and marketing licence in the European Union (for a recent review, see [14]).…”
Section: Introductionmentioning
confidence: 99%
“…[5][6][7][8][9] Compared with the single projection image of mammography, in digital breast tomosynthesis, multiple low-dose projections are acquired from different angles and subsequently used to produce stacks of image slices, which can in part reduce the mammography overlapping effect, however, with rather low resolution in the z-direction. 10 Dedicated breast computed tomography (B-CT) systems have been recently introduced, which can provide cross-sectional images with high isotropic spatial resolution and better soft tissue (ST) contrast. Breast computed tomography has the potential to further improve breast lesion detection and characterization compared with mammography and tomosynthesis.…”
mentioning
confidence: 99%