2018 IEEE 19th Workshop on Control and Modeling for Power Electronics (COMPEL) 2018
DOI: 10.1109/compel.2018.8460017
|View full text |Cite
|
Sign up to set email alerts
|

Digital Average Current Programmed Mode Control for Multi-level Flying Capacitor Converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
3
0
2

Year Published

2018
2018
2021
2021

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(5 citation statements)
references
References 12 publications
0
3
0
2
Order By: Relevance
“…Substituindo ( 7) em ( 6) e, após manipulações matemáticas, obtém-se o conjunto de equações (8). A equação (9)é obtida realizando a divisão entre as equações de (8).…”
Section: A Estratégia De Controle Cpm Para O Conversor Buckunclassified
See 1 more Smart Citation
“…Substituindo ( 7) em ( 6) e, após manipulações matemáticas, obtém-se o conjunto de equações (8). A equação (9)é obtida realizando a divisão entre as equações de (8).…”
Section: A Estratégia De Controle Cpm Para O Conversor Buckunclassified
“…Dentre as estratégias mencionadas, um método amplamente implementado pela indústriaé o controle por corrente programada (Current Programmed Mode Control -CPM) ou também conhecido por controle por corrente de pico. Essa estratégiaé utilizada tanto para implementação em circuitos integrados [7], [9], [12], até conversores multi-níveis [8], [13], possuindo uma grande versatilidade em termos de níveis de potência e tensão do sistema.…”
Section: Introductionunclassified
“…The flying capacitor voltage stabilization mechanism used in conjunction with the average CPM controller is similar to the technique used in conventional voltage mode control [28], which is explored in detail in [32]. The mechanism is briefly reviewed in this section.…”
Section: Flying Capacitor Controlmentioning
confidence: 99%
“…The main challenge for 3LFC converter control is the maintenance of flying capacitor voltage balance, which is required to obtain a symmetric inductor current waveform in each half of a switching period and to preserve the voltage levels equal on the switching devices. For this purpose, various control methods are proposed for voltage regulated 3LFC converters [2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17] in the literature. The traditional control methods for DC-DC converters such as current mode and voltage mode control are advantageous for 3LFC buck converters due to their technical maturity.…”
Section: Introductionmentioning
confidence: 99%
“…However, the traditional current mode control methods, which are average current mode (ACM) and peak current mode control methods, for 3LFC buck converters are subject to FC voltage instabilities. To the best of the authors' knowledge, for ACM control of 3LFC buck converters, two control schemes, which are named duty-cycle offsetting and average command offsetting, are reported in Lu et al [12] so far.…”
Section: Introductionmentioning
confidence: 99%