1977
DOI: 10.1021/ac50019a717
|View full text |Cite
|
Sign up to set email alerts
|

Digital Analysis of Electronic Absorption Spectre

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

1994
1994
2013
2013

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 15 publications
0
2
0
Order By: Relevance
“…Since it is well established that NPE obeys the NEER principle38 (Scheme 1), the fluorescence decay functions used in KFA are given by 7 (A Am) = aa expHV) + ab exp(-V) (12) where ( )( «,0, «") is the fluorescence intensity at a specific «" from the conformer mixture (the bar over the symbol is used to identify quantities referring to the response of the conformer mixture) prepared by excitation at X«xc as a function of time following a excitation pulse. The biexponential decay parameters give conformer lifetimes t* = kA{ and tb = kB~\ and the preexponential factors give ratios of intensities of the fast and slow components.7•27 _ A_a _/a(\xe) 7**(Xem)^M "'V/AxAAnA (13) In eq 13 the //(X»c) represent fractions of conformers i = A or B molecules excited at each specific Xexc /AJ = f4H7=1"/fl(x««) (14) > where «(XeXC) are effective molar absorptivity coefficients of the conformer mixture, and the FfKm) represent fluorescence intensities of each conformer at Xem.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Since it is well established that NPE obeys the NEER principle38 (Scheme 1), the fluorescence decay functions used in KFA are given by 7 (A Am) = aa expHV) + ab exp(-V) (12) where ( )( «,0, «") is the fluorescence intensity at a specific «" from the conformer mixture (the bar over the symbol is used to identify quantities referring to the response of the conformer mixture) prepared by excitation at X«xc as a function of time following a excitation pulse. The biexponential decay parameters give conformer lifetimes t* = kA{ and tb = kB~\ and the preexponential factors give ratios of intensities of the fast and slow components.7•27 _ A_a _/a(\xe) 7**(Xem)^M "'V/AxAAnA (13) In eq 13 the //(X»c) represent fractions of conformers i = A or B molecules excited at each specific Xexc /AJ = f4H7=1"/fl(x««) (14) > where «(XeXC) are effective molar absorptivity coefficients of the conformer mixture, and the FfKm) represent fluorescence intensities of each conformer at Xem.…”
Section: Discussionmentioning
confidence: 99%
“…Figure12. Arrhenius plots of k,p based on eq 30 and the /s in TableIV: Xe,c = 316 nm (O) and X,,c = 355 nm ( ).…”
mentioning
confidence: 99%