2019
DOI: 10.1038/s41598-019-56184-6
|View full text |Cite
|
Sign up to set email alerts
|

Diffusion-weighted Renal MRI at 9.4 Tesla Using RARE to Improve Anatomical Integrity

Abstract: Diffusion-weighted magnetic resonance imaging (DWI) is a non-invasive imaging technique sensitive to tissue water movement. By enabling a discrimination between tissue properties without the need of contrast agent administration, DWI is invaluable for probing tissue microstructure in kidney diseases. DWI studies commonly make use of single-shot Echo-Planar Imaging (ss-EPI) techniques that are prone to suffering from geometric distortion. The goal of the present study was to develop a robust DWI technique tailo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 69 publications
0
5
0
Order By: Relevance
“…Application of diffusion‐sensitizing gradients to RARE may face the issue that motion during the Stejskal–Tanner preparation experiment may violate the Carr–Purcell–Meiboom–Gill condition, 40 which may induce signal loss and errors in diffusion measurement. Split‐echo RARE 28 successfully addresses this problem and improves the anatomic integrity of renal DWI. The train of refocusing pulses results in an imaging speed and RF power deposition handicap over EPI 41 .…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Application of diffusion‐sensitizing gradients to RARE may face the issue that motion during the Stejskal–Tanner preparation experiment may violate the Carr–Purcell–Meiboom–Gill condition, 40 which may induce signal loss and errors in diffusion measurement. Split‐echo RARE 28 successfully addresses this problem and improves the anatomic integrity of renal DWI. The train of refocusing pulses results in an imaging speed and RF power deposition handicap over EPI 41 .…”
Section: Discussionmentioning
confidence: 99%
“…The evaluation of geometric distortion was performed following the approach reported by Periquito et al 28 First, the kidney outlines were manually segmented in T2W RARE images to define the distortion‐free reference. Subsequently, the reference contours were superimposed to nondiffusion‐sensitized images of ss‐EPI and four‐shot EPI acquisitions.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Other readouts apart from EPI can be use in DWI such as rapid acquisition with relaxation enhancement (RARE) (Fig. 3) which is less prone to suffering from geometric distortion specially at ultrahigh magnetic fields [6].…”
Section: Notesmentioning
confidence: 99%
“…A RARE readout can be used to minimize the magnetic susceptibility artifacts which cause geometric distortions on DW-EPI. DW-RARE is not commercially available, pulse programming skills are needed to implement it[6]…”
mentioning
confidence: 99%