Diffusion-weighted Imaging of the Liver with MultiplebValues: Effect of Diffusion Gradient Polarity and Breathing Acquisition on Image Quality and Intravoxel Incoherent Motion Parameters—A Pilot Study

Abstract: Purpose:To optimize intravoxel incoherent motion (IVIM) diffusion-weighted (DW) imaging by estimating the effects of diffusion gradient polarity and breathing acquisition scheme on image quality, signal-to-noise ratio (SNR), IVIM parameters, and parameter reproducibility, as well as to investigate the potential of IVIM in the detection of hepatic fibrosis. Materials and Methods:In this institutional review board-approved prospective study, 20 subjects (seven healthy volunteers, 13 patients with hepatitis C vir… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

19
187
5

Year Published

2013
2013
2017
2017

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 168 publications
(211 citation statements)
references
References 25 publications
19
187
5
Order By: Relevance
“…Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9)(10)(11)(12)(19)(20)(21)24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50). Current review cannot draw conclusion which one is better than others, nor can the mean values be compared (Figure 8).…”
Section: Image Post-processing Methods For Ivim Parametersmentioning
confidence: 99%
See 2 more Smart Citations
“…Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9)(10)(11)(12)(19)(20)(21)24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50). Current review cannot draw conclusion which one is better than others, nor can the mean values be compared (Figure 8).…”
Section: Image Post-processing Methods For Ivim Parametersmentioning
confidence: 99%
“…Dyvorne et al (15) found that RT sequence has higher image quality than FB sequences, the latter being much more prone to motionrelated blurring. Additionally, left lobe may be more prone to cardiac motion artifacts which potentially can alter diffusion measurement (15). However, Barbieri et al found that the use of RT did not have a significant effect on the measured parameter values (37).…”
Section: Respiratory Triggering (Rt) or Free-breathing (Fb) For Livermentioning
confidence: 99%
See 1 more Smart Citation
“…Large values of standard deviation of D * was the one of the reasons. Some reports showed D * and PF are not reproducible [9][10][11]. In addition, some reports showed that the standard deviation and its coefficient of variation in D * and PF are large [7,11].…”
Section: Discussionmentioning
confidence: 99%
“…Some reports showed D * and PF are not reproducible [9][10][11]. In addition, some reports showed that the standard deviation and its coefficient of variation in D * and PF are large [7,11]. 2 were suitable to evaluate microperfusion [1,12].…”
Section: Discussionmentioning
confidence: 99%