1994
DOI: 10.1016/1352-2310(94)00189-r
|View full text |Cite
|
Sign up to set email alerts
|

Diffusion scrubber technique used for measurements of atmospheric ammonia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
0
1

Year Published

1995
1995
2015
2015

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(18 citation statements)
references
References 33 publications
0
16
0
1
Order By: Relevance
“…The FAL and RISOE systems use a fluorescence detection technique (Blatter et al, 1993;Sørensen et al, 1994). The analytical detection is based on the reaction between ophthaldialdehyde, a reducing agent and ammonia to produce a fluorescent compound (Rapsomanikis et al, 1988).…”
Section: Detection and Response Characteristicsmentioning
confidence: 99%
“…The FAL and RISOE systems use a fluorescence detection technique (Blatter et al, 1993;Sørensen et al, 1994). The analytical detection is based on the reaction between ophthaldialdehyde, a reducing agent and ammonia to produce a fluorescent compound (Rapsomanikis et al, 1988).…”
Section: Detection and Response Characteristicsmentioning
confidence: 99%
“…The liquid was heated to 60 • C to enhance the formation of the fluorescent compound before injection into the fluorescence detector. Detailed information of the WEDD and the analytical 4580 K. Hansen et al: Ammonia emissions from deciduous forest after leaf fall system can be found in Sorensen et al (1994). To prevent freezing of the fluent when air temperature was near freezing point, the water was mixed with ethanol.…”
Section: Relaxed Eddy Accumulation (Rea)mentioning
confidence: 99%
“…The aqueous NH 3 solution from the two WEDDs was pumped with a constant flow directly to the analytical detection system which was located at the top floor of a scaffolding tower. A fluorescent compound was produced by mixing o-phthaldialdehyde (OPA), sulphite, and the aqueous NH 3 solution (Sorensen et al, 1994). The liquid was heated to 60 • C to enhance the formation of the fluorescent compound before injection into the fluorescence detector.…”
Section: Relaxed Eddy Accumulation (Rea)mentioning
confidence: 99%
“…Diffusion-based methods such as the diffusion denuder [11][12][13][14] and the diffusion scrubber 4,15,16 are used for the separate sampling of gaseous and particulate species in the atmosphere. Using a diffusion denuder, water soluble gases are absorbed into the thin film of the absorbent, typically water or an aqueous solution, which flows over the surface of chemically-treated glass.…”
Section: 10mentioning
confidence: 99%