Diffusing wave spectroscopy in Maxwellian fluids

Abstract: We present a critical assessment of the diffusing wave spectroscopy (DWS) technique for obtaining the characteristic lengths and for measuring the loss and storage moduli of a reasonable well-known wormlike micelle (WM) system. For this purpose, we tracked the Brownian motion of particles using DWS embedded in a Maxwellian fluid constituted by a wormlike micellar solution made of cetyltrimethylammonium bromide (CTAB), sodium salicylate (NaSal), and water. We found that the motion of particles was governed by t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

9
110
3

Year Published

2013
2013
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 63 publications
(122 citation statements)
references
References 29 publications
9
110
3
Order By: Relevance
“…The inconsistent results obtained for G'LL are most likely due to some cantilever inhomogeneities or to non-ideal clamping, effects which are not yet taken into account in the model. Nevertheless, except for G'LL, the cantilever-based shear modulus measurements seem to corroborate and extend the Diffusion Wave Spectroscopy reference measurements [33] up to 100 kHz. …”
Section: Use Of Hydrodynamic Force Study For the Measurement Of Fluidsupporting
confidence: 78%
See 1 more Smart Citation
“…The inconsistent results obtained for G'LL are most likely due to some cantilever inhomogeneities or to non-ideal clamping, effects which are not yet taken into account in the model. Nevertheless, except for G'LL, the cantilever-based shear modulus measurements seem to corroborate and extend the Diffusion Wave Spectroscopy reference measurements [33] up to 100 kHz. …”
Section: Use Of Hydrodynamic Force Study For the Measurement Of Fluidsupporting
confidence: 78%
“…An example of characterization of CTAB (CetylTrimethylAmmonium Bromide) with microcantilevers at 19°C is given in Fig. 10, as are measurements made with the same concentration of polymer by Galvan-Miyoshi et al at 22°C [33] and cone-plate measurements made at 19°C. As expected, unlike Newtonian fluids, G' is no longer negligible.…”
Section: Use Of Hydrodynamic Force Study For the Measurement Of Fluidmentioning
confidence: 98%
“…Fig. 1D shows a SEM image of the FISP formed from precursor 50 (FISP 50 ), exhibiting entangled, branched, and multiconnected networks.…”
Section: Effect Of Salt On Branched Wormlike Micellesmentioning
confidence: 99%
“…However, the resolution of cryo-TEM tends to be decreased due to the vitreous ice layer within the sample. Taking these factors into consideration, we performed both cryo-TEM and TEM microscopy of FISP 50 , as shown in Fig. 3.…”
Section: Effect Of Salt On Branched Wormlike Micellesmentioning
confidence: 99%
See 1 more Smart Citation