2008
DOI: 10.1111/j.1460-9592.2008.02595.x
|View full text |Cite
|
Sign up to set email alerts
|

Difficult intubation in a small for gestational age newborn by bonfils fiberscope

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(15 citation statements)
references
References 6 publications
0
15
0
Order By: Relevance
“…There have been isolated reports of the use of the Bonfils as a rescue device in difficult intubation of small babies. This includes a case of a neonate with mandibular hypoplasia and large tongue , and an 18‐month‐old boy with partial trisomy 1 mosaic . The authors of these reports highlighted the ease of use of this instrument in small babies, and the atraumatic nature of the device.…”
Section: Discussionmentioning
confidence: 99%
“…There have been isolated reports of the use of the Bonfils as a rescue device in difficult intubation of small babies. This includes a case of a neonate with mandibular hypoplasia and large tongue , and an 18‐month‐old boy with partial trisomy 1 mosaic . The authors of these reports highlighted the ease of use of this instrument in small babies, and the atraumatic nature of the device.…”
Section: Discussionmentioning
confidence: 99%
“…It is available in 2, 3.5 , and 5 mm external diameters, sizes with the 2 mm being appropriate for most neonatal intubations. Caruselli et al describe the successful intubation of a small for gestational age full-term neonate with failed direct laryngoscopy using the Bonfi ls fi berscope using a 2.5 mm endotracheal tube [ 40 ]. Bein et al described their experience with the Bonfi ls fi berscope Anesthesia Challenges for the Diffi cult and Critical Neonatal Airway in 55 children (mean age 6 years); they reported an increased failure rate, and increased time to successful intubation in children with normal airways [ 41 ].…”
Section: Optical Stylletesmentioning
confidence: 97%
“…[3][4] The instrument is available in various sizes and its design makes intubation easy under direct visualization. [3][4] The instrument is available in various sizes and its design makes intubation easy under direct visualization.…”
Section: Intubation Using a "Bonfils Fiberscope" In A Patient With Pfmentioning
confidence: 99%
“…3 Although there are data relating to airway management in the preburn center setting, 4 and also data regarding the long-term sequela of airway burns, 5 there are no strict guidelines for the FIGURE 1. 1,2 Airway obstruction can result from deposition of the products of incomplete combustion and the sloughing of cellular debris.…”
Section: Extensive Mucosal Sloughing and Tracheobronchial Cast After mentioning
confidence: 99%