2013
DOI: 10.1016/j.electacta.2012.09.102
|View full text |Cite
|
Sign up to set email alerts
|

Differential pulse voltammetric determination of paracetamol in tablet and urine samples at a micro-crystalline natural graphite–polystyrene composite film modified electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
20
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
10

Relationship

2
8

Authors

Journals

citations
Cited by 71 publications
(23 citation statements)
references
References 43 publications
2
20
0
Order By: Relevance
“…In this case, the slope value of À 56.0 mV pH À 1 closely approximates the theoretical value of À 59.0 mV pH À 1 from the Nernst equation, indicating that equal amounts of proton and electron transfer occur in the electrode reactions. This result agrees well with those obtained at multiwalled carbon nanotubes (MWCNTs) [52], graphite/polystyrene [53], and Nafion/TiO 2 -graphene [54] modified electrodes.…”
Section: Optimization Of Detection Conditions and Electro-catalytic Asupporting
confidence: 93%
“…In this case, the slope value of À 56.0 mV pH À 1 closely approximates the theoretical value of À 59.0 mV pH À 1 from the Nernst equation, indicating that equal amounts of proton and electron transfer occur in the electrode reactions. This result agrees well with those obtained at multiwalled carbon nanotubes (MWCNTs) [52], graphite/polystyrene [53], and Nafion/TiO 2 -graphene [54] modified electrodes.…”
Section: Optimization Of Detection Conditions and Electro-catalytic Asupporting
confidence: 93%
“…Acetaminophen (AC), as an anti-pyretic agent, is widely used all over the world for relieving pain and fever [23,24]. Although there is some evidence showing no propensity to be addictive by ingesting AC, overdose of AC will lead to toxic metabolite accumulation which may induce morbidity and mortality in humans [25,26].…”
Section: Introductionmentioning
confidence: 99%
“…The detection limit was calculated to be 14 nM by the equation 3σ/b, where σ is the standard deviation of the blank and b is the slope of the calibration plot [34]. A comparison between the analytical performance of the present method and some previous literature methods for the determination of AP are given in Table 1 [35][36][37][38][39][40][41][42][43][44][45]. As can be seen from Table1, the proposed method showed wide linear ranges and low detection limit for determination of AP.…”
Section: Calibration Plotmentioning
confidence: 98%