2012
DOI: 10.1364/oe.20.027094
|View full text |Cite
|
Sign up to set email alerts
|

Differential measurement scheme for Brillouin Optical Correlation Domain Analysis

Abstract: We newly propose and experimentally demonstrate a differential measurement scheme for Brillouin optical correlation domain analysis, where the difference between Brillouin gain spectra constructed by a normal and a phase-modulated Brillouin pump waves are analyzed to measure local Brillouin frequencies in optical fibers. In experiments, a five-fold enhancement in the spatial resolution is obtained compared to an ordinary BOCDA system under the same modulation parameters, as a result of the improved dynamic ran… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
24
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 76 publications
(25 citation statements)
references
References 13 publications
1
24
0
Order By: Relevance
“…While providing mm-scale resolution [26], initial B-OCDA was restricted to an unambiguous measurement range of a few hundreds of resolution points only, limited by the separation between neighboring periodic peaks. The measurement range was since extended using more elaborate frequency modulation profiles [27,28].…”
Section: Introductionmentioning
confidence: 99%
“…While providing mm-scale resolution [26], initial B-OCDA was restricted to an unambiguous measurement range of a few hundreds of resolution points only, limited by the separation between neighboring periodic peaks. The measurement range was since extended using more elaborate frequency modulation profiles [27,28].…”
Section: Introductionmentioning
confidence: 99%
“…For noise suppression in data acquisition, we applied a differential measurement scheme that has been used for the BGS analysis in a Brillouin sensor [11]. A phase modulation (inset A in Fig.…”
mentioning
confidence: 99%
“…Another way to reduce the background spectrum was invented by Professor K. Y. Song et al [52], which is called the "differential measurement scheme" [52]. In this scheme, a phase modulator is introduced in either the pump or probe path.…”
Section: Differential Measurement Scheme To Reduce Background Spectrummentioning
confidence: 99%
“…By subtracting the spectrum with the PM from the spectrum without the PM, the signal spectrum is featured, as shown in Figure 34c. This is the mechanism to reduce the background spectrum in the "differential modulation scheme" [52] or the "phase modulation scheme" [84]. Figure 33.…”
Section: Bocdr Systems With Performance Improvement Schemesmentioning
confidence: 99%