Differential Effect of 3-Dimensional Color Doppler Echocardiography for the Quantification of Mitral Regurgitation According to the Severity and Characteristics

Abstract: Although the flow quantification using 3D-CDE has been proposed to overcome the inherent limitations of 2D-CDE, 9,12-15 its technical limitations, such as multiple gated acquisition and time-consuming manual processing, prevent it from becoming widely adopted into daily clinical practice.Recently, advances in technology of 3D-CDE provide the option of semiautomated MR quantification based on the 3D-PISA method, and its results could be potentially more accurate than 2D-PISA method in quantifying MR. 16Backgrou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
27
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 56 publications
(27 citation statements)
references
References 39 publications
0
27
0
Order By: Relevance
“…The software that we used allows an almost fully automatic quantification of the PISA volume without the need of correction formulas for the PISA shape or any angle correction factor. It has mainly been used for quantifying mitral regurgitation, showing increased accuracy when compared to 2D methods . Recent works also successfully applied it for quantifying tricuspid regurgitation and mitral stenosis with similar findings .…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The software that we used allows an almost fully automatic quantification of the PISA volume without the need of correction formulas for the PISA shape or any angle correction factor. It has mainly been used for quantifying mitral regurgitation, showing increased accuracy when compared to 2D methods . Recent works also successfully applied it for quantifying tricuspid regurgitation and mitral stenosis with similar findings .…”
Section: Discussionmentioning
confidence: 99%
“…Three‐dimensional PISA volume was calculated more than a month after the acquisition, using a dedicated software (eSie PISA; Siemens Medical Solutions USA, Inc). A detailed description of the software as well as its in vitro and in vivo validation can be found elsewhere . After selecting the frame with the largest and more well‐defined PISA in mid‐diastole, selecting an aliasing velocity (by shifting the baseline) and setting the seed points, this software automatically determines the PISA volume—Figure .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…3D echocardiography (3DE) MR assessment could have potential advantages for quantifying MR due to fewer geometric assumptions; however, 3DE PISA-derived Rvol has shown mixed results in terms of correlations with CMR [56, 57]. …”
Section: Mitral Valvementioning
confidence: 99%
“…However, differentiating moderate from severe MR remains challenging in the absence of a clear definition of the MR severity and its quantification . Accurate quantification not only prevents undergrading of patients with identified severe MR as having nonsevere MR, it also prevents referral of patients to surgical centers for severe MR by echocardiography that reveal nonsevere MR on advanced evaluation, for example, by transesophageal echocardiography (TEE) or cardiac magnetic resonance (CMR) …”
Section: Introductionmentioning