Different Power Settings of LLLT on the Repair of the Calcaneal Tendon

Abstract: Low-level laser therapy resulted in significantly greater amounts of type III collagen (output powers of 60 mW or more) and type I collagen (output power of 80 mW), however, no significant differences between groups were found in the realignment of collagen fibers.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
32
0
2

Year Published

2013
2013
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(37 citation statements)
references
References 31 publications
3
32
0
2
Order By: Relevance
“…Group C: rats subjected to surgical procedures without tendon lesion and hAM application simulation; Group I: animals subjected to surgical procedures, including tendon injury, and hAM application simulation; and Group T: animals subjected to surgical procedures, including tendon injury, and hAM application. The tendon injury was induced by direct trauma in animals of groups I and T using a mini guillotine (Physiology Laboratory at the University of Paraíba Valley), according to the protocol used by Neves et al 14 . The sample size of 5 subjects per group was validated by calculating the power (beta), obtaining values of 0.86 for the inflammatory cell counts and 0.99 for fibroblast count.…”
Section: ■ Methodsmentioning
confidence: 99%
“…Group C: rats subjected to surgical procedures without tendon lesion and hAM application simulation; Group I: animals subjected to surgical procedures, including tendon injury, and hAM application simulation; and Group T: animals subjected to surgical procedures, including tendon injury, and hAM application. The tendon injury was induced by direct trauma in animals of groups I and T using a mini guillotine (Physiology Laboratory at the University of Paraíba Valley), according to the protocol used by Neves et al 14 . The sample size of 5 subjects per group was validated by calculating the power (beta), obtaining values of 0.86 for the inflammatory cell counts and 0.99 for fibroblast count.…”
Section: ■ Methodsmentioning
confidence: 99%
“…It is important to note that this study utilized a constant power output and power density and only altered the time of treatment in order to study different energy density effects. It is unclear if a constant time with variable power density would have had the same outcome, as previous studies have shown that altering the power density can have significant biological effects . It is clear that both parameters are likely to have marked impact on outcome.…”
Section: Discussionmentioning
confidence: 99%
“…Wood et al also found that ultrasound, LLLT, and the combined use of LLLT and ultrasound resulted in greater synthesis of type I collagen (but not type III collagen) [25]. Moreover, different power settings of low-level laser treatment might also contribute to the significantly differential expressions of type I and type III collagen [26]. Thus, we believed, under certain settings of laser parameters, low-level laser could predominantly affect the synthesis of type I collagen from tenocytes.…”
Section: Discussionmentioning
confidence: 99%