2008
DOI: 10.1080/00032710802122115
|View full text |Cite
|
Sign up to set email alerts
|

Different Lubricating Oil Treatments for the Determination of Cu, Cr, Fe, Ni, Sb, Pb, and Zn by HR-CS FAAS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
13
0

Year Published

2009
2009
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(15 citation statements)
references
References 13 publications
1
13
0
Order By: Relevance
“…These two last strategies can be used to improve sensitivity (Amorim Filho & Gomes Neto, 2008). Additionally, in comparison with conventional atomic absorption spectrometry, the technique has other inherent advantages such as random access to all wavelengths in the range from 189 nm to 900 nm, and effective and flexible background correction by means of mathematical algorithms (Huang, Becker-Ross, Florek, Heitmann, & Okruss, 2006).…”
Section: Introductionmentioning
confidence: 99%
“…These two last strategies can be used to improve sensitivity (Amorim Filho & Gomes Neto, 2008). Additionally, in comparison with conventional atomic absorption spectrometry, the technique has other inherent advantages such as random access to all wavelengths in the range from 189 nm to 900 nm, and effective and flexible background correction by means of mathematical algorithms (Huang, Becker-Ross, Florek, Heitmann, & Okruss, 2006).…”
Section: Introductionmentioning
confidence: 99%
“…The wavelength-integrated absorbance (WIA) and the sum of absorbances of molecular lines were used to enhance the sensitivity and determine B, P, and S in 12 medicinal plants [18]. Other applications of HR-CS FAAS are the analysis of P and K in liquid fertilizers [19], the determination of Cu, Pb, Cd, and Mn in sediments [20], the sequential determination of Sb and Pb in pewter alloys [21], and the analysis of Cu, Cr, Fe, Ni, Pb, Sb, Zn [22], Al, Ba, Mo, Si, and V [23] in lubricating oils after the use of different sample pretreatment procedures. Raposo et al [24] evaluated the side pixel registration approach and the use of alternate lines of Fe for sequential determination of Cu, Fe, Mn, and Zn in soil extracts (diethylenetriaminepentaacetic acid extracting solution).…”
mentioning
confidence: 99%
“…On the other hand, high metal concentration has been related with the friction and corrosion of the mechanical components of engines. Amorim Filho and Gomes Neto [34] studied three sample preparation procedures: microwave-assisted acid decomposition, direct dilution in kerosene, and oil-in-water emulsion for metal determination by HR-CS-FAAS. Considering direct dilution, it was evaluated the kerosene/light mineral oil ratio to prepare standard solutions since sample and light mineral oil present different viscosities and it can cause accuracy errors.…”
Section: Fuelsmentioning
confidence: 99%