2014
DOI: 10.1002/jmri.24744
|View full text |Cite
|
Sign up to set email alerts
|

Differences in hyperpolarized 3He ventilation imaging after 4 years in adults with cystic fibrosis

Abstract: For two CF subjects, VDP was significantly worse at baseline and worsened over 4 years, which was in agreement with a greater number of hospitalizations and clinic visits. These results are limited by the very small sample size, but the strong VDP correlation with longitudinal changes in FEV1 generates the hypothesis that abnormal VDP may temporally precede FEV1 decline in CF subjects; this must be tested in a larger CF study.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
22
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(23 citation statements)
references
References 23 publications
1
22
0
Order By: Relevance
“…There will be a growing role for HP gas MRI in assessing therapy response and disease progression in CF [133, 269271] and pediatric lung diseases in general as this technology, and MRI as a whole, are actively extended to study childhood [256, 261, 272] and neonatal [272, 273] lung diseases.…”
Section: Applications Of Hyperpolarized Gas Mri To Pre-clinical Anmentioning
confidence: 99%
“…There will be a growing role for HP gas MRI in assessing therapy response and disease progression in CF [133, 269271] and pediatric lung diseases in general as this technology, and MRI as a whole, are actively extended to study childhood [256, 261, 272] and neonatal [272, 273] lung diseases.…”
Section: Applications Of Hyperpolarized Gas Mri To Pre-clinical Anmentioning
confidence: 99%
“…Following this, hyperpolarized helium-3 MRI (HP 3 He MRI) has been examined in multiple settings and has shown high sensitivity for the detection of ventilation impairments [34][35][36][37][38][39][40][41][42][43][44]. This typically requires production of hyperpolarized gas on site which is then mixed with nitrogen and administered to patients with a one litre Tedlar Bag.…”
Section: Hyperpolarized Helium-3 Mrimentioning
confidence: 99%
“…In humans, stunning 3-D data sets of the lung with resolution of a few millimeters can now be acquired in a ten-second breath-hold (Qing et al , 2015). A variety of diseases have been studied, among them cystic fibrosis (Flors et al , 2016; Mentore et al , 2005; Paulin et al , 2015) (see Fig. 22), asthma (Kruger et al , 2014; Tustison et al , 2010), and emphysema (Kirby et al , 2013; Quirk et al , 2011; Spector et al , 2005).…”
Section: Magnetic Resonance Imagingmentioning
confidence: 99%