Differences Between Enzymatic and Diazo Methods for Measuring Direct Bilirubin

Abstract: Summary: An orthodox diazo method is popularly used for measuring bilirubin. On the other hand, an enzymatic method which employs bilirubin oxidase, has also been in use for considerable time. We have often found disparities between direct bilirubin values obtained with the enzymatic and the diazo methods. To determine the cause of these disparities, bilirubin subtractions were analysed and classified into two types by HPLC. Samples showing great differences contained conjugated, unconjugated and δ bilirubins … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 15 publications
(4 reference statements)
0
3
0
Order By: Relevance
“…Plasma (EDTA) levels of total bilirubin, HbA 1c and γ-glutamyltransferase (GGT) were determined using an automated analyser (Hitachi 917, Roche Diagnostics, Basel, Switzerland). Total bilirubin was measured as the plasma concentration expressed in μmol/l using the Diazo method [24].…”
Section: Study Participantsmentioning
confidence: 99%
“…Plasma (EDTA) levels of total bilirubin, HbA 1c and γ-glutamyltransferase (GGT) were determined using an automated analyser (Hitachi 917, Roche Diagnostics, Basel, Switzerland). Total bilirubin was measured as the plasma concentration expressed in μmol/l using the Diazo method [24].…”
Section: Study Participantsmentioning
confidence: 99%
“…Using diazo methods for direct bilirubin, both conjugated and delta bilirubin are measured photometrically and thus the value is a little higher than conjugated bilirubin alone. 8 …”
Section: Methodsmentioning
confidence: 99%
“…Although the differences between the [Bt] results obtained by these 2 methods were statistically significant, the authors believe that in the measurement of bilirubin in animals with high [Bt], such small differences may be tolerable because they have no relevance to the diagnosis or monitoring of the disease. It has been shown 18 that the difference between the diazo and oxidase methods is at least partially due to incomplete oxidation of Bc by the oxidase methods.…”
mentioning
confidence: 99%