Difference of vascular healing between bioabsorbable-polymer and durable-polymer new generation drug-eluting stents: an optical coherence tomographic analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
2

Relationship

3
3

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 35 publications
0
10
0
Order By: Relevance
“…There are several reports comparing vessel healing after stent implantation between different coronary stents, 5,11) but the stents have many differences including not only the number of connectors but strut thickness, stent material, shape of hoops, drugs, and polymers. The present study is the first attempt to show the effect of only the number of connectors on mid-term vessel healing and stent expansion using unique design of Promus PREMIER stents.…”
Section: Discussionmentioning
confidence: 99%
“…There are several reports comparing vessel healing after stent implantation between different coronary stents, 5,11) but the stents have many differences including not only the number of connectors but strut thickness, stent material, shape of hoops, drugs, and polymers. The present study is the first attempt to show the effect of only the number of connectors on mid-term vessel healing and stent expansion using unique design of Promus PREMIER stents.…”
Section: Discussionmentioning
confidence: 99%
“…To measure inter-observer reproducibility, the percentage of uncovered struts and the percentage of malapposed struts were compared using the Bland-Altman method in 10 randomly selected OCT image. [17]…”
Section: Oct Image Analysismentioning
confidence: 99%
“…We previously published the details of the OCT analysis. [7,8] All variables were analyzed at lesion level. In brief, the cross-sectional OCT images were analyzed at 1-mm intervals within the entire target segment of the pre-procedural, post-procedural, and 3-month follow-up OCT data.…”
Section: Oct Image Analysismentioning
confidence: 99%
“…The inter-observer reproducibility of the OCT image analysis in our institution were shown in a previous article. [7] Statistical Analysis No sample size calculation was performed due to the absence of previous data. Categorical variables are stated as numbers (percentages) and compared using a Pearson's chi-squared test.…”
Section: Oct Image Analysismentioning
confidence: 99%
See 1 more Smart Citation