2022
DOI: 10.3390/bioengineering9080379
|View full text |Cite
|
Sign up to set email alerts
|

Diet Shift May Trigger LuxS/AI-2 Quorum Sensing in Rumen Bacteria

Abstract: Recent studies have revealed that LuxS/AI-2 quorum sensing (QS) is the most universal cell-to-cell communication in rumen bacteria; however, it remains unknown how they respond to nutritional stress from a diet shift. This study aimed to explore whether a diet shift could trigger rumen bacterial LuxS/AI-2 QS and its influences on rumen fermentation characteristics and bacterial community diversity and composition. A total of fifteen Hu sheep were selected to undergo a pre-shift diet (Pre, concentrate to forage… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
0
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 55 publications
0
0
0
Order By: Relevance
“…A total of 54 examples of high-purity and high-quality DNA were delivered to Allwegene Gene Technology Co., LTD (Nanjing, China) for subsequent amplification and sequencing. The V3-V4 region was selected as the target region for amplification to reveal the bacterial diversity and bacterial community, with the barcoded primers according to Wei et al [22] as follows: 338F (5 -ACTCCTACGGGAGGCAGCAG-3 ) and 806R (5 -GGACTACNNGGGTATCTAAT-3 ). The amplification procedure and its reaction system were the same as described in Qiu et al [21].…”
Section: Parameter Determinationmentioning
confidence: 99%
See 1 more Smart Citation
“…A total of 54 examples of high-purity and high-quality DNA were delivered to Allwegene Gene Technology Co., LTD (Nanjing, China) for subsequent amplification and sequencing. The V3-V4 region was selected as the target region for amplification to reveal the bacterial diversity and bacterial community, with the barcoded primers according to Wei et al [22] as follows: 338F (5 -ACTCCTACGGGAGGCAGCAG-3 ) and 806R (5 -GGACTACNNGGGTATCTAAT-3 ). The amplification procedure and its reaction system were the same as described in Qiu et al [21].…”
Section: Parameter Determinationmentioning
confidence: 99%
“…The raw data were analyzed using QIIME 2 (https://qiime2.org/, accessed on 30 December 2022; [23]). The criteria of data filtration were according to Wei et al [22], which allowed sequence lengths of between 250 bp and 500 bp and a quality score greater than 20, as well as removing sequences with ambiguous bases or those mismatched to primers and barcodes. The filtered sequences were merged into tags by Paired-End reAd mergeR (PEAR, version 0.9.6, [24]), where the minimum overlap was set to 10 bp, and allowed a maximum mismatch rate of 0.10.…”
Section: Parameter Determinationmentioning
confidence: 99%