1995
DOI: 10.1080/02786829408959735
|View full text |Cite
|
Sign up to set email alerts
|

Diesel Exhaust/Mine Dust Virtual Impactor Personal Aerosol Sampler: Design, Calibration and Field Evaluation

Abstract: A virtual impactor personal aerosol sampler (VIPAS)cyclone pass through a 0.8-pm cutpoint virtual imhas been developed for use in diesel-equipped mines to pactor with the particles larger than and smaller than collect size-separated samples of diesel exhaust and 0.8 p m (mine dust and diesel exhaust particles, respecmine dust particles in the respirable size range. This tively) collected on two 37-mm filter cassettes. The sampler consists of three stages: a 10-mm cyclone, a sampling flow rate is 2 L/min so as … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

1996
1996
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(6 citation statements)
references
References 11 publications
(8 reference statements)
0
6
0
Order By: Relevance
“…9 There is a growing need for both a detailed size classification and chemical characterization of the personal exposure to PM. Various personal monitoring systems have been developed [10][11][12] to measure some size fractions of PM (i.e., PM 2.5 and PM 10 ), as well as chemical components such as some inorganic species (e.g., sulfates, nitrates) and elemental and organic carbon.…”
Section: Introductionmentioning
confidence: 99%
“…9 There is a growing need for both a detailed size classification and chemical characterization of the personal exposure to PM. Various personal monitoring systems have been developed [10][11][12] to measure some size fractions of PM (i.e., PM 2.5 and PM 10 ), as well as chemical components such as some inorganic species (e.g., sulfates, nitrates) and elemental and organic carbon.…”
Section: Introductionmentioning
confidence: 99%
“…The 50% cutpoint of the impactor was calculated from the corresponding St value of 0.47. This value has been used by Marple et al (1995) for a minor-to-total flow ratio of 0.1 based on numerical simulations and experimental studies. It should be noted that a more precise determination (i.e., an experimental verification) of the cutpoint in our system was not considered essential to our studies.…”
Section: Ultrafine Particlesmentioning
confidence: 99%
“…33,39 The accuracy, precision, and sensitivity of the PEM samplers have been well characterized. 26,28,[56][57][58][59] Hourly PM 2.5 concentrations measured using the DustTrak were averaged over 12-hr periods and were compared to the 12-hr integrated PM 2.5 PEM measurements. The total number of PEM-DustTrak pairs was 35 in the summer and 42 in the winter.…”
Section: Ambient Validation Tests For Dusttrak Aerosol Monitormentioning
confidence: 99%