2005
DOI: 10.1016/j.jmr.2005.08.002
|View full text |Cite
|
Sign up to set email alerts
|

Dielectric resonator-based resonant structure for sensitive ESR measurements at high-hydrostatic pressures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
20
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(21 citation statements)
references
References 44 publications
(62 reference statements)
1
20
0
Order By: Relevance
“…The details of such resonators are described in the paper [13]. In our laboratory the special dielectric resonators for EPR studies (both standard and under pressure) have been constructed.…”
Section: Review High Pressure Techniques Used In the Paramagnetic Rementioning
confidence: 99%
See 2 more Smart Citations
“…The details of such resonators are described in the paper [13]. In our laboratory the special dielectric resonators for EPR studies (both standard and under pressure) have been constructed.…”
Section: Review High Pressure Techniques Used In the Paramagnetic Rementioning
confidence: 99%
“…However the DACs were also used in the electron paramagnetic resonance studies [6]. Recently a gasketed sapphire anvil cell (SAC) for electron spin resonance (EPR) measurements under high-hydrostatic pressures has been constructed [13]. The EPR was tested for a of 2,2-diphenyl-1-picrylhydrazyl…”
Section: Techniquementioning
confidence: 99%
See 1 more Smart Citation
“…The pressure is one of the most important parameters in the solid state physics because it changes the interactions between the electron spins continuously and it sometimes leads to novel physical phenomena [19][20][21][22]. Although high-pressure ESR is a powerful means to observe the spin system subjected to the pressure microscopically, it usually needs specialized equipments [10][11][12][13][14][15][16][17][18]. On the contrary, the SQUID-ESR can be applied to the high-pressure ESR very easily.…”
Section: Application To High-pressure Measurementmentioning
confidence: 99%
“…Moreover, the system can be applied to the high pressure ESR measurement without difficulty by using a piston cylinder pressure cell. This is another advantageous point as compared with other ESR systems because the high-pressure ESR usually needs specialized equipments [10][11][12][13][14][15][16][17][18]. In this paper, we show the outline of the system and its application example.…”
Section: Introductionmentioning
confidence: 99%