Dielectric metrology with coaxial sensors

Abstract: Coaxial sensors are used in applications that require accurate and traceable measurements of complex permittivity. For example, coaxial sensors are often used for measurement of the complex permittivity of tissue equivalent materials (TEMs) used in specific absorption rate (SAR) measurements of exposure to RF fields. It is therefore important that well-founded metrological techniques for their use are developed and published. Although there are many published papers on coaxial sensors, few discuss the experime… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
106
0
1

Year Published

2009
2009
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 94 publications
(107 citation statements)
references
References 55 publications
(77 reference statements)
0
106
0
1
Order By: Relevance
“…[12]. the reflection measurements fitted κ values deviate slightly from directly measured data due to imperfections of the probes [19]. Accordingly, experimental conductivities were chosen as a starting approximation in the fitting procedure but were generally 1-2% greater than the fitted values used.…”
Section: Resultsmentioning
confidence: 99%
“…[12]. the reflection measurements fitted κ values deviate slightly from directly measured data due to imperfections of the probes [19]. Accordingly, experimental conductivities were chosen as a starting approximation in the fitting procedure but were generally 1-2% greater than the fitted values used.…”
Section: Resultsmentioning
confidence: 99%
“…In practice, conductivities obtained by fitting differ slightly from the directly measured values due to fringing field effects that arise from the geometry of the VNA probe. [43,50] Accordingly, as in our previous work, [26,43,51] experimental k values were taken as the starting point for the conductivity correction but were adjusted slightly to give the best fit to the dielectric data. While these adjustments are small for the present RTILs (typically < 10 % in k), they are larger than those observed for typical aqueous electrolyte solutions.…”
Section: Methodsmentioning
confidence: 99%
“…During the measurement a swept frequency signal was transmitted from the VNA into the liquid via the coaxial line, and the reflection coefficient was recorded. The amplitude and the phase of  were fed into a computer program, which utilised a modal analysis [25,[35][36][37] to calculate the real (dielectric constant, ɛ') and imaginary parts (dielectric loss, ɛ'') of the complex permittivity. Figure 2 shows the differential weight loss with temperature for Coal A treated for 120 minutes at a range of powers from 0.75 kW to 3 kW.…”
Section: And Commercial Coke 2)mentioning
confidence: 99%