2017
DOI: 10.1109/tpel.2016.2602232
|View full text |Cite
|
Sign up to set email alerts
|

Dielectric Loss Factor Measurement in Power Systems Based on Sampling Sequence Reconstruction Approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…Moreover, the transient overvoltage of primary voltage, partial discharge, and resonance overvoltage may cause irreversible damage to insulation dielectric, reduce the breakdown strength of CVT and directly lead to the capacitor's breakdown in severe cases. In contrast to insulation dielectric having many mature research methods 6,7,8,9 , capacitors do not have appropriate parameters to accurately diagnose the state of capacitors. Therefore, this paper presents capacitor breakdown, the main form of deterioration in CVT.…”
Section: 1the Insulation Structure Of Cvtmentioning
confidence: 99%
“…Moreover, the transient overvoltage of primary voltage, partial discharge, and resonance overvoltage may cause irreversible damage to insulation dielectric, reduce the breakdown strength of CVT and directly lead to the capacitor's breakdown in severe cases. In contrast to insulation dielectric having many mature research methods 6,7,8,9 , capacitors do not have appropriate parameters to accurately diagnose the state of capacitors. Therefore, this paper presents capacitor breakdown, the main form of deterioration in CVT.…”
Section: 1the Insulation Structure Of Cvtmentioning
confidence: 99%
“…The hardware methods mainly include zero comparison [10 ] and Schering Bridge [11 ], which have some drawbacks such as the low precision, difficult compensation and poor anti‐interference ability. The software methods mainly include correlation function algorithm [12 ], higher‐order sine fitting algorithm [13 ], fast Fourier transform (FFT) [14 ], fundamental harmonic separation algorithm [15 ] and so on, which are characteristic of the low cost, high precision and good anti‐interference ability, so they are the main method to calculate the power angle.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, some insulation condition monitoring methods with brand-new concepts have been proposed. Li proposed a dielectric loss factor measurement approach based on sampling sequence reconstruction for capacitive equipment 10 , this method also needs to monitoring a) Electronic mail: wfr101@163.com the voltage and current synchronously, and it is not particular to CVTs, the specific type of insulation faults cannot be diagnosed. Daryani proposed an evidence theory-based insulation aging identification approach for CVTs 11 , the output voltage, the negative sequence components, the zero sequence components and the park transformation parameter of groups of CVTs are considered to generate the indicators of insulation condition, but the case studies illustrate that this method could only detect more than three capacitors outage, the dielectric loss is not considered in it.…”
Section: Introductionmentioning