2002
DOI: 10.3390/s21000384
|View full text |Cite
|
Sign up to set email alerts
|

Dibenzocyclamnickel(II) as Ionophore in PVC-Matrix for Ni2+-Selective Sensor

Abstract: Abstract:The tetramethyldibenzocyclam derivative, was synthesized and characterized and was used for fabrication of potentiometric sensor for Ni 2+ metal ion.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2005
2005
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(13 citation statements)
references
References 29 publications
0
13
0
Order By: Relevance
“…Nickel concentrations of one ppm are deadly to aquatic environment (Allway, 2000). Nickel leads to a lack of growth, it has effects on the blood (high number of red blood cells), affects the production of protein in the kidneys (Gupta et al, 2002) and affects plant life through its influence on the solubility of ion exchange in plants (Allway, 2000). The results in table 6 indicate that, based on the correction coefficient r, RSD%, Erel and Re%, the atomic absorption method is more accurate and sensitive to the estimation of nickel ions than spectral methods for all the measured samples.…”
Section: +2mentioning
confidence: 99%
See 1 more Smart Citation
“…Nickel concentrations of one ppm are deadly to aquatic environment (Allway, 2000). Nickel leads to a lack of growth, it has effects on the blood (high number of red blood cells), affects the production of protein in the kidneys (Gupta et al, 2002) and affects plant life through its influence on the solubility of ion exchange in plants (Allway, 2000). The results in table 6 indicate that, based on the correction coefficient r, RSD%, Erel and Re%, the atomic absorption method is more accurate and sensitive to the estimation of nickel ions than spectral methods for all the measured samples.…”
Section: +2mentioning
confidence: 99%
“…The results in table 9 indicate that, based on the correction coefficient r, RSD%, Erel and Re%, the spectral method is more accurate and sensitive to the estimation of nickel ions than the atomic absorption method for all the measured samples. This is due to the oxidation of iron (Fe +2 ) to (Fe +3 ) by air within the atomic absorption oven which leads to an overlap in the absorption pattern, giving a lack in accuracy of this method for this element (Gupta et al, 2002). …”
Section: +2mentioning
confidence: 99%
“…Then it was treated with 2-3 mL 1:1 nitric acid solution and cooled, filtered and made up to 25 mL in a volumetric flask. 3.0 mL of prepared sample was added to centrifuge tube and the analysis was carried out in line with general procedure section 25 .…”
Section: Chocolate Samplesmentioning
confidence: 99%
“…(Very high selectivity was observed for the macrocycle 47c toward Cu(II).) The authors report on the use of the complex 98 [101] as ionophore in the polymer matrix of a Ni(II)-selective sensor. (The sensor was used successfully as indicator electrode during the potentiometric titration of Ni(II).)…”
Section: Complexing Ability and Possible Practical Applications Of DImentioning
confidence: 99%