Diagnostic Value of the First and Second Derivatives of the Arterial Pressure Pulse in Aortic Valve Disease and in Hypertrophic Subaortic Stenosis

Abstract: The brachial arterial dp/dt was continuously computed by means of an electronic differentiating circuit in 117 patients and 23 normal subjects. The peak dp/dt averaged 1092±372 (S.D.) mm. Hg/sec. in 32 patients with idiopathic hypertrophic subaortic stenosis, 547±94 mm. Hg/sec. in six patients with discrete subvalvular subaortic stenosis, 811±185 mm. Hg/sec. in 23 normal subjects, 358±85 mm. Hg/sec. in 29 patients with valvular aortic stenosis, 724±212 mm. Hg/sec. in 25 patients with combined aortic stenosis a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
9
1
1

Year Published

1965
1965
1998
1998

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 38 publications
(13 citation statements)
references
References 27 publications
1
9
1
1
Order By: Relevance
“…The rate of neck chamber pressure change was low, relative to the normal maximum human arterial dP/dt [811 ± 39 mm Hg/sec in the brachial artery (Mason et al, 1964)], and to the rate of onset of the sustained stimuli I applied in the present study (maximum dP/dt: ± 2000 to 2500 mm Hg/ sec). In the study of Thron and coworkers (then- Figs.…”
Section: Comparisons With Results From Other Studiescontrasting
confidence: 53%
“…The rate of neck chamber pressure change was low, relative to the normal maximum human arterial dP/dt [811 ± 39 mm Hg/sec in the brachial artery (Mason et al, 1964)], and to the rate of onset of the sustained stimuli I applied in the present study (maximum dP/dt: ± 2000 to 2500 mm Hg/ sec). In the study of Thron and coworkers (then- Figs.…”
Section: Comparisons With Results From Other Studiescontrasting
confidence: 53%
“…With these stimulus parameters, responses began to decline when the dP/dt fell below -200 mmHg/sec. Comparable response patterns were observed in three subjects in whom the onset of neck suction DWAIN L. ECKBERG coincided with the P wave (when arterial dP/dt would have been nearly zero (Mason et al 1964)), and in two subjects in whom neck suction began 0 40 and 0 45 sec after the onset of the P wave. This suggests that the reponse pattern observed was not due merely to superimposition of the experimental stimulus upon the rapid rise of the natural arterial pressure.…”
Section: Resultsmentioning
confidence: 76%
“…It was assumed on the basis of previous studies (Eckberg, 1976) that the dP/dt measured in the neck chamber slightly exceeded that actually delivered to the carotid sheath. Therefore, two rates of pressure change, -1200 and -550 mmHg/sec were chosen to bracket the normal range of human arterial dP/dt (found by Mason, Braunwald, Ross & Morrow (1964) to be about 440-1180 mmHg/sec in the brachial artery), and one level, -300 mmHg/sec, was chosen to fall below the normal range. Intensities of -20 to -60 mmHg were applied for 0-6 sec, 0-75-0-85 sec before the anticipated appearance of the next P wave (see below).…”
Section: Introductionmentioning
confidence: 99%
“…34 -36 Because of this rapid emptying, the brachial artery dp/dt and the d 2 p/dt 2 are higher in patients with obstructive HCM than in normal control subjects. 37 ␤-Blocker prevention of the B-agonist-induced rise in dp/dt has been shown. 1,2 Figure 5.…”
Section: Comparison With Control Subjectsmentioning
confidence: 93%