2022
DOI: 10.1055/s-0042-1754332
|View full text |Cite
|
Sign up to set email alerts
|

Diagnostic Testing for von Willebrand Disease: Trends and Insights from North American Laboratories over the Last Decade

Abstract: Accurate diagnosis of von Willebrand disease (VWD) depends on the quality, precision, and variability of the laboratory assays. The North American Specialized Coagulation Laboratory Association (NASCOLA) is a provider of external quality assessment (EQA) for approximately 60 specialized coagulation laboratories in North America. In this report, NASCOLA EQA data from 2010 to 2021 are reviewed for trends in methodology and precision among various assays. In particular, recent ASH ISTH NHF WFH (American Society o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
53
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 10 publications
(54 citation statements)
references
References 28 publications
(45 reference statements)
1
53
0
Order By: Relevance
“…The ASH ISTH NHF WFH guidelines 50 feel it is more important to capture all type 2 cases, even if falsely capturing some type 1 cases, since findings “suggestive” of type 2 VWD usually result in further discriminatory testing, such as VWF multimers or genetic analysis. Interestingly, NASCOLA data 18 tended to confirm 0.7 as a preferred cut-off with assays dominant in North America, whereas UK NEQAS data seemed to favor 0.6 as the better cut-off. 17 CAP could not provide data on cut-off values due to sample issues.…”
Section: Learning From Eqamentioning
confidence: 98%
See 4 more Smart Citations
“…The ASH ISTH NHF WFH guidelines 50 feel it is more important to capture all type 2 cases, even if falsely capturing some type 1 cases, since findings “suggestive” of type 2 VWD usually result in further discriminatory testing, such as VWF multimers or genetic analysis. Interestingly, NASCOLA data 18 tended to confirm 0.7 as a preferred cut-off with assays dominant in North America, whereas UK NEQAS data seemed to favor 0.6 as the better cut-off. 17 CAP could not provide data on cut-off values due to sample issues.…”
Section: Learning From Eqamentioning
confidence: 98%
“…16 18 VWF:GPIbM and VWF:GPIbR are performed by far fewer laboratories (15 and 6% in NASCOLA data, respectively). 18 VWF:CB is also performed by few laboratories (18%, NASCOLA data), 18 and this is exclusively by ELISA (CLIA based VWF assays not being available in North America).…”
Section: Learning From Eqamentioning
confidence: 99%
See 3 more Smart Citations