2019
DOI: 10.1007/s00330-019-06377-4
|View full text |Cite
|
Sign up to set email alerts
|

Diagnostic outcome and safety of CT-guided core needle biopsy for mediastinal masses: a systematic review and meta-analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
22
0
3

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(27 citation statements)
references
References 49 publications
2
22
0
3
Order By: Relevance
“…In three patients, major pneumothorax occurred requiring therapy by a chest tube. With respect to technical success, diagnostic yield and complication rate associated with CT fluoroscopy-guided percutaneous core needle biopsies of mediastinal masses, our study agrees with other similar studies [ 3 , 5 , 6 , 11 , 12 , 14 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 ]. For instance, de Margerie-Mellon et al reported a technical success rate of 100% and a diagnostic yield of 87% in 285 consecutive patients which is one of the largest studies on this subject.…”
Section: Discussionsupporting
confidence: 91%
“…In three patients, major pneumothorax occurred requiring therapy by a chest tube. With respect to technical success, diagnostic yield and complication rate associated with CT fluoroscopy-guided percutaneous core needle biopsies of mediastinal masses, our study agrees with other similar studies [ 3 , 5 , 6 , 11 , 12 , 14 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 ]. For instance, de Margerie-Mellon et al reported a technical success rate of 100% and a diagnostic yield of 87% in 285 consecutive patients which is one of the largest studies on this subject.…”
Section: Discussionsupporting
confidence: 91%
“…Success Rates and QI Thresholds for Image-Guided Percutaneous Needle Biopsies(65)(66)(67)(68)(69)(70)(71)(72)(73)(74)(75)(76)(77)(78)(79)(80)(81)(82)(83)(84) …”
mentioning
confidence: 99%
“…An Komplikationen sind vorwiegend Blutungen, Pneumothorax, Hämoptysen und Hämatothorax zu nennen. Diese treten selten auf (13 %) und sind sehr selten schwerwiegend (2 %) [37]. Hierbei ist zu beachten, dass 20-G-Nadeln den besten Kompromiss zwischen diagnostischer Genauigkeit und Komplikationsrate aufweisen.…”
Section: Computertomografiegestützte Interventionenunclassified
“…Es sollten mindestens 3 Gewebsproben entnommen werden. Mit den o. g. Voraussetzungen lässt sich eine diagnostische Genauigkeit von 94 % erzielen [37].…”
Section: Computertomografiegestützte Interventionenunclassified
See 1 more Smart Citation