2019
DOI: 10.1007/s12350-017-0961-5
|View full text |Cite
|
Sign up to set email alerts
|

Diagnostic implications of CZT SPECT and impact of CT attenuation correction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 24 publications
0
6
0
Order By: Relevance
“…Bearing in mind that still the ideal radiopharmaceutical for scintigraphic diagnosis of NETs has not been discovered, there are a lot of them under investigation[ 30 - 32 ] such as: 99m Tc-EDDA--tricine-HYNIC-NATE, 99m Tc-EDDA/HYNIC-Tyrosine3-octreotate, 99m Tc-6-hydrazinopyridine-3-carboxylic acid (0)-octreotide or indium-111 (tetraxetan- tyrosine3-octreotate), 99m Tc-demotate or 99m Tc-P829. Wider application of hybrid systems (SPECT/CT, SPECT/MRI) as well as new cadmium-zinc-telluride SPECT and SPECT/CT cameras increased and widened application and increased the accuracy of somatostatin receptor scintigraphy[ 33 , 34 ]. These radiopharmaceuticals can also be used for radio-guided surgery thus increasing sensitivity and specificity of the method[ 35 ].…”
Section: Discussionmentioning
confidence: 99%
“…Bearing in mind that still the ideal radiopharmaceutical for scintigraphic diagnosis of NETs has not been discovered, there are a lot of them under investigation[ 30 - 32 ] such as: 99m Tc-EDDA--tricine-HYNIC-NATE, 99m Tc-EDDA/HYNIC-Tyrosine3-octreotate, 99m Tc-6-hydrazinopyridine-3-carboxylic acid (0)-octreotide or indium-111 (tetraxetan- tyrosine3-octreotate), 99m Tc-demotate or 99m Tc-P829. Wider application of hybrid systems (SPECT/CT, SPECT/MRI) as well as new cadmium-zinc-telluride SPECT and SPECT/CT cameras increased and widened application and increased the accuracy of somatostatin receptor scintigraphy[ 33 , 34 ]. These radiopharmaceuticals can also be used for radio-guided surgery thus increasing sensitivity and specificity of the method[ 35 ].…”
Section: Discussionmentioning
confidence: 99%
“…In the absence of AC, prone position can reduce attenuation artifacts. 6 Recently, it has been demonstrated the possibility to measure MBF and MFR with CZT cameras.…”
Section: See Related Article Pp 755-768mentioning
confidence: 99%
“…Effect of CT attenuation correction on the diagnostic accuracy of CZT-SPECT. This figure is reprinted from Peters et al6 and is licenced under CC BY 4.0.…”
mentioning
confidence: 99%
“…One of the most common artifacts in MPI is caused by the attenuation of photons by the patient’s body [ 11 ]. Computed tomography-attenuation correction (CT-AC) is a validated approach to improve diagnostic accuracy and risk stratification [ 12 ]. According to the American Society of Nuclear Cardiology’s recommendation, attenuation correction should be performed in all patients [ 13 ].…”
Section: Introductionmentioning
confidence: 99%
“…The new systems have improved count sensitivity and image quality [ 14 ]. The use of CZT-SPECT in clinical practice is on the rise due to its benefits of enhanced image accuracy and reduced scanning duration compared to conventional SPECT systems using sodium iodide (NaI) crystals [ 12 ].…”
Section: Introductionmentioning
confidence: 99%