2007
DOI: 10.1016/j.ophtha.2007.01.015
|View full text |Cite
|
Sign up to set email alerts
|

Diagnostic Ability of Heidelberg Retina Tomograph 3 Classifications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
22
1

Year Published

2009
2009
2019
2019

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(23 citation statements)
references
References 25 publications
0
22
1
Order By: Relevance
“…7 Importantly, the sensitivity of the ISNT rule in our study and the earlier study 7 is higher than other current HRT diagnostic algorithms (i.e., MRA, GPS, and Mikelberg, Burk, and Bathija linear discriminant functions, which have reported sensitivities of ,90% in clinic-and population-based studies). 16,17,19,30,32,33 Thus, the high sensitivity and NPV of the ISNT rule per se revealed in our analysis indicated potential utility in population-based glaucoma evaluation.…”
Section: Discussionmentioning
confidence: 57%
See 1 more Smart Citation
“…7 Importantly, the sensitivity of the ISNT rule in our study and the earlier study 7 is higher than other current HRT diagnostic algorithms (i.e., MRA, GPS, and Mikelberg, Burk, and Bathija linear discriminant functions, which have reported sensitivities of ,90% in clinic-and population-based studies). 16,17,19,30,32,33 Thus, the high sensitivity and NPV of the ISNT rule per se revealed in our analysis indicated potential utility in population-based glaucoma evaluation.…”
Section: Discussionmentioning
confidence: 57%
“…In addition, disc size is known to influence the diagnostic performance of HRT classification algorithms, such as the Moorfields regression analysis (MRA), glaucoma probability score (GPS), and linear discriminant functions. [16][17][18][19] Whether the performance of the ISNT rule on the HRT is influenced by the spectrum of optic disc sizes in the population is unclear. Therefore, a second objective of this study was to evaluate the impact of disc area on the performance of the ISNT rule and its variants.…”
Section: Superior (S) Nasal (N)mentioning
confidence: 99%
“…Ferreras et al [13] reported lower sensitivities of both algorithms in early glaucomatous eyes, especially for MRA [10]. Higher diagnostic accuracies were seen in cases of advanced visual loss and glaucoma severity, for both MRA and GPS [14].…”
Section: Discussionmentioning
confidence: 99%
“…Direct population comparison is difficult as majority of the studies are done in Caucasian populations [13, 15-18]. Coops et al [15] studied 95 Caucasian healthy controls (mean deviation of -0.1 decibels, range +2.5 to -3.7) and 121 Caucasian glaucoma patients (mean deviation of -3.6 decibels, range +2.0 to -9.9).…”
Section: Discussionmentioning
confidence: 99%
“…30 HRT could outperform stereophotography in one study, but the authors used non-mydriatic stereophotographs, which are not of optimum quality. 31 The diagnostic performance of MRA compared with GPS was judged to be similar in some studies, 32,33 while others reported a better performance of GPS 34 or MRA. 35 Regarding SLP (GDx), two high-quality studies were detected (i.e.…”
Section: Literature Reviewmentioning