2022
DOI: 10.29354/diag/145500
|View full text |Cite
|
Sign up to set email alerts
|

Diagnosis of three types damages to the ventilation system

Abstract: The article is devoted to solving of urgent problem to eliminate damage in ventilation system. That is caused by non-adequate long range, stagnant unventilated areas in the room existance and high noise level in the premises at air distribution by swirled air flow, compact air jet, flat air stream and rectangular air jet. A noise level of air supply with swirled air flow, compact air jet, flat air jet and rectangular air stream in the room has been investigated. It is shown that in order to achieve the maximum… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 34 publications
0
4
0
Order By: Relevance
“…The positive cooling effect, through a greater convective heat exchange with the human body, without the input of additional energy for cooling, which is desirable in the warm season, can be achieved through increased airflow. The description of the solutions based on periodic change in the volume flow rate and the initial velocity of air diffusers are described in [65,66]. This current article proposes, as one of the thermomodernization measure, the utilization of the original, proprietary technical solution, namely, the two-flow air diffuser (TFAD) presented in Figure 4 [67].…”
Section: Modernization Of Building Installationmentioning
confidence: 99%
See 1 more Smart Citation
“…The positive cooling effect, through a greater convective heat exchange with the human body, without the input of additional energy for cooling, which is desirable in the warm season, can be achieved through increased airflow. The description of the solutions based on periodic change in the volume flow rate and the initial velocity of air diffusers are described in [65,66]. This current article proposes, as one of the thermomodernization measure, the utilization of the original, proprietary technical solution, namely, the two-flow air diffuser (TFAD) presented in Figure 4 [67].…”
Section: Modernization Of Building Installationmentioning
confidence: 99%
“…Connecting the electric actuator, which is controlled from the automation unit, enables the smooth change in volumetric air flow and intensity. As a result, the device works with air volume, which can be increased with a stable air velocity maintained within regulatory limits without any disruptions, and thus, the TFAD is dedicated to variable air volume ventilation systems (VAV) [66].…”
Section: Modernization Of Building Installationmentioning
confidence: 99%
“…In addition, air distribution is very important in energy performance [27][28][29][30][31]. The importance rises at variable air volume ventilation [32][33][34][35][36][37]. The device has no simultaneously operated neighbouring air inlet and outlet comparably with a recuperative one, which avoids the exhausting inlet air compared with a recuperative analogue.…”
Section: Introductionmentioning
confidence: 99%
“…The proper microclimate [1][2][3][4][5] in the room is provided by heating and natural or mechanical ventilation systems [6][7][8] with compliance with energy savings requirements [9][10][11][12]. The base element in the natural ventilation system is usually a duct in the premises, which is led above the roof of the building.…”
Section: Introductionmentioning
confidence: 99%