Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2009
DOI: 10.1378/chest.08-1859
|View full text |Cite
|
Sign up to set email alerts
|

Diagnosis of Obstructive Sleep Apnea Syndrome and Its Outcomes With Home Portable Monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
69
0
6

Year Published

2009
2009
2017
2017

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 113 publications
(79 citation statements)
references
References 35 publications
1
69
0
6
Order By: Relevance
“…[46][47][48]52,55,81,88,89,98,104 In addition, 7 of 14 inlaboratory studies showed a decline in sensitivity and an increase in specificity, and 2 studies showed an increase in area under the ROC curve. 47,48,51,52,58,[61][62][63][65][66][67][69][70][71] We found no significant difference in baseline characteristics between the 2 groups of patients in all 8 studies that reported disease management after the diagnosis by either test.…”
Section: Diagnostic Accuracy Of Sleep Testsmentioning
confidence: 99%
“…[46][47][48]52,55,81,88,89,98,104 In addition, 7 of 14 inlaboratory studies showed a decline in sensitivity and an increase in specificity, and 2 studies showed an increase in area under the ROC curve. 47,48,51,52,58,[61][62][63][65][66][67][69][70][71] We found no significant difference in baseline characteristics between the 2 groups of patients in all 8 studies that reported disease management after the diagnosis by either test.…”
Section: Diagnostic Accuracy Of Sleep Testsmentioning
confidence: 99%
“…35,53,54,81,86,88,93,96,116 The required signals and minimum durations included nasal pressure flow and oximetry for at least 3 hours 88,93,116 or 4 hours 53,81,86,96 and single-channel nasal airflow recording for a minimum of 3 hours 35 or only 2 hours. 54 The diagnostic accuracy of the cardiorespiratory devices compared against PSG for the detection of OSA at different AHI cutoff points was relatively high.…”
mentioning
confidence: 99%
“…1,[33][34][35] For the GoToSleep study, full unattended polysomnography is conducted using the portable Safiro device (Compumedics) providing data on: electroencephalogram (EEG), electrooculogram, chin electromyogram, thoracic and abdominal displacement, airflow, finger pulse oximeter, electrocardiogram, body position, leg movement, and audio recording of participant's snoring. Trained research staff members travel to the patient to apply the sleep monitor in the location that is most convenient for the patient (usually the patient's home).…”
Section: Intervention Patientsmentioning
confidence: 99%