Diagnosis of Breast Cancer Using Electrical Impedance Tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
21
0
2

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(23 citation statements)
references
References 0 publications
0
21
0
2
Order By: Relevance
“…. , V L ] T can be calculated by solving the boundary value problem defined by (1) and (2). Due to the limited voltage rejection ratio of electronic circuit, a large common voltage may reduce the measurement sensitivity.…”
Section: Direct Problemmentioning
confidence: 99%
See 1 more Smart Citation
“…. , V L ] T can be calculated by solving the boundary value problem defined by (1) and (2). Due to the limited voltage rejection ratio of electronic circuit, a large common voltage may reduce the measurement sensitivity.…”
Section: Direct Problemmentioning
confidence: 99%
“…One of the commonly seen applications of EIT is to reconstruct the inclusions in a homogeneous background medium, e.g. detecting tumor [1,2], monitoring respiratory process [3,4], imaging air bubbles in liquids [5,6]. With prior knowledge of the conductivity values of the inclusions, the boundary of the inclusions can be parameterized by a set of shape coefficients, then reconstructed from EIT measurements.…”
Section: Introductionmentioning
confidence: 99%
“…Finally, the definition of specificity and sensitivity of the proposed method is planned to be achieved in a validation stage with real breast tissue results obtained through experimental clinical trials. The validation procedure is planned through result comparison with mammography or ultrasound techniques [43][44][45][46][47].…”
mentioning
confidence: 99%
“…A larger study [26] was conducted consisting of an in vivo trial on 117 female patients. The subjects included healthy patients and patients with mastopathy, benign tumours, or breast cancer.…”
Section: Eit and Breast Cancer Detectionmentioning
confidence: 99%
“…The MEIK electroimpedance mammograph was used in the two studies mentioned above. The device uses a circular array of 256 electrodes to image the conductivity over the breast [26]. The T-SCAN device is another clinically available device [27].…”
Section: Eit and Breast Cancer Detectionmentioning
confidence: 99%