2022
DOI: 10.1097/rti.0000000000000664
|View full text |Cite
|
Sign up to set email alerts
|

Diagnosing Pulmonary Embolism With Computed Tomography Pulmonary Angiography

Abstract: Purpose: Computed tomography pulmonary angiography (CT-PA) is frequently used in the diagnostic workup of pulmonary embolism (PE), even in highly radiosensitive patient populations. This study aims to assess CT-PA with reduced z-axis coverage (compared with a standard scan range covering the entire lung) for its sensitivity for detecting PE and its potential to reduce the radiation dose. Materials and Methods:We retrospectively analyzed 602 consecutive CT-PA scans with definite or possible PE reported. A reduc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(1 citation statement)
references
References 27 publications
0
1
0
Order By: Relevance
“…CTPA is conventionally performed by acquiring images of the whole thorax after intravenous CM administration in the pulmonary arterial phase, with the objective of optimal opacification of pulmonary arteries up to the subsegmental branches [ 15 ]. In a recent publication [ 16 ], shortening the scan range (upper edge of the aortic arch and the lower hemidiaphragm) could provide an estimated average radiation dose reduction by 48% without significant loss of sensitivity for PE detection. This is of particular importance in populations that are particularly radiosensitive such as breast irradiation in young females.…”
Section: Multimodality Imaging Approach To Pulmonary Thromboembolic D...mentioning
confidence: 99%
“…CTPA is conventionally performed by acquiring images of the whole thorax after intravenous CM administration in the pulmonary arterial phase, with the objective of optimal opacification of pulmonary arteries up to the subsegmental branches [ 15 ]. In a recent publication [ 16 ], shortening the scan range (upper edge of the aortic arch and the lower hemidiaphragm) could provide an estimated average radiation dose reduction by 48% without significant loss of sensitivity for PE detection. This is of particular importance in populations that are particularly radiosensitive such as breast irradiation in young females.…”
Section: Multimodality Imaging Approach To Pulmonary Thromboembolic D...mentioning
confidence: 99%