2006
DOI: 10.1152/ajpheart.00031.2006
|View full text |Cite
|
Sign up to set email alerts
|

Developmental changes in hemodynamics of uterine artery, utero- and umbilicoplacental, and vitelline circulations in mouse throughout gestation

Abstract: In human pregnancy, abnormal placental hemodynamics likely contribute to the etiology of early-onset preeclampsia and fetal intrauterine growth restriction. The mouse is increasingly being deployed to study normal and abnormal mammalian placental development, yet the placental hemodynamics in normal pregnancy in mice is currently unknown. We used ultrasound biomicroscopy to noninvasively image and record Doppler blood velocity waveforms from the maternal and embryonic placental circulations in mice throughout … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

10
104
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 110 publications
(116 citation statements)
references
References 53 publications
10
104
0
Order By: Relevance
“…Fetal-placental units were imaged over a strict 20-min time period, with a minimum of three units being analyzed in each pregnancy. Blood velocity within the umbilical artery, vein, and placenta was measured (45). Fetal hearts were visualized in B-mode and Doppler measurements were undertaken to determine the E/A wave ratio and myocardial performance index (MPI) (26).…”
Section: Methodsmentioning
confidence: 99%
“…Fetal-placental units were imaged over a strict 20-min time period, with a minimum of three units being analyzed in each pregnancy. Blood velocity within the umbilical artery, vein, and placenta was measured (45). Fetal hearts were visualized in B-mode and Doppler measurements were undertaken to determine the E/A wave ratio and myocardial performance index (MPI) (26).…”
Section: Methodsmentioning
confidence: 99%
“…A thick layer of pre-warmed coupling gel (Ecogel 100; ECO-MED Pharmaceutical, ON, Canada) was applied over the area to be imaged using a 40-MHz transducer probe (Vevo 770, VisualSonics Inc., ON, Canada). 22,26 Body temperature was maintained at 36-37°C by the warmed platform. Maternal heart and respiration rates (ECG/Tm/Resp) were collected using a Physiological Controller Unit.…”
Section: Ultrasound Proceduresmentioning
confidence: 99%
“…22 SA flows, characterized by pulsed waveforms, were imaged at the mesometrial decidual edge in 2-4 implantation sites of each gd10-18 pregnancy. Peak systolic velocities of fetal umbilical arteries (UmA) were recorded before these arteries entered the placenta and branched into chorionic plate arteries (CPA) that run across the placental surface and branch into the major intraplacental arteries (IPA) in developing primary villi.…”
Section: Ultrasound Proceduresmentioning
confidence: 99%
See 2 more Smart Citations