2018
DOI: 10.2322/tastj.16.137
|View full text |Cite
|
Sign up to set email alerts
|

Development of X-ray Generator for Active X-ray Fluorescence Spectroscopy of Future Lunar Landing Mission and Its Contribution to Lunar Science

Abstract: Active X-ray fluorescence Spectrometer (AXS) is designed and developed as an elemental analyzer to induce fluorescence X-rays from rock samples without radioactive sources for future lunar and planetary landing missions in Japan. Pyroelectric crystal is applied for X-ray generator because of its compact package, lightweight, low-power consumption, and radioactive source-free. As the X-ray emission intensity from Pyroelectric X-ray Generator (PXG) is not strong enough to be applied for space missions, we have b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
4
1

Year Published

2022
2022
2022
2022

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(7 citation statements)
references
References 28 publications
(48 reference statements)
2
4
1
Order By: Relevance
“…Large X-ray counts were measured during the cooling phase, i.e., X-ray emission from the Cu target. This tendency was common in the previous studies 8, [10][11][12] . Some irregular increases and stops of X-ray counts appear in the 1 cm × 5 cm (Fig.…”
Section: Time Profiles and Energy Spectra Of X-ray Countssupporting
confidence: 64%
See 2 more Smart Citations
“…Large X-ray counts were measured during the cooling phase, i.e., X-ray emission from the Cu target. This tendency was common in the previous studies 8, [10][11][12] . Some irregular increases and stops of X-ray counts appear in the 1 cm × 5 cm (Fig.…”
Section: Time Profiles and Energy Spectra Of X-ray Countssupporting
confidence: 64%
“…This effect is large when the crystal is large. Our previous works obtained large X-ray counts with a cylindrical support may be due to these effects 11 .…”
Section: Electric Field Distributions At Around the Lt Crystalmentioning
confidence: 96%
See 1 more Smart Citation
“…Besides, PXG should allow shorter measurement time than radioisotopes: one Amptek COOL‐X is equivalent to 2 mCi source (data from manufacturer) and the geometry of our instrument allows to use 6 PXG. If we use the same geometry but with latest PXG, which is 70 times more intense than COOL‐X, 11 we would have a source equivalent to ~840 mCi, 21 times the activities of the radioisotopes sources onboard APXS 14 instrument on Mars.…”
Section: Pxg As a Source Of Choicementioning
confidence: 99%
“…This type of source has already been used in energy dispersive X‐ray fluorescence instruments 9,10 . The use of PXG for planetary XRF instrument has been studied previously with focus on source development 11,12 . The present work uses a commercial source and is focused on the improvement of detector resolution, measurement reproducibility, and peak selection algorithm implementation.…”
Section: Introductionmentioning
confidence: 99%