2014
DOI: 10.1541/ieejias.134.618
|View full text |Cite
|
Sign up to set email alerts
|

Development of Wavelength Converter for Arc Light Detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 1 publication
0
4
0
Order By: Relevance
“…An arc discharge occurs in a pantograph because of the opening of the contact wire and contact strip. The contact wire and contact strip are melted by the arc discharge . A decrease in equipment efficiency occurs because of the erosion of the electrode .…”
Section: Re‐strike Phenomenon Analysis For DC Circuit Breaker and Elementioning
confidence: 99%
“…An arc discharge occurs in a pantograph because of the opening of the contact wire and contact strip. The contact wire and contact strip are melted by the arc discharge . A decrease in equipment efficiency occurs because of the erosion of the electrode .…”
Section: Re‐strike Phenomenon Analysis For DC Circuit Breaker and Elementioning
confidence: 99%
“…There are various types of arc-detection measurement systems currently on the market in Japan. They include, for example, a visible-light detecting system that uses a plastic optical fiber for the arc light path, and an ultraviolet-detecting system that uses a wavelength converter with an interference filter and fluorescent glass attached to the head of a plastic optical fiber 6 (referred to as the unit type here after), and an ultraviolet detection system without any plastic optical fiber (referred to as the UV detection type here after). Ultraviolet detection systems are becoming increasingly popular because they are not influenced by sunlight.…”
Section: Arcing Due To Contact Loss and Measurement Systemmentioning
confidence: 99%
“…Separation between contact strip and contact wire is called pantograph bounce; when pantograph bounce happens during current collection, arc discharge occurs between contact strip and contact wire. This discharge is a high‐temperature free arc with complex movement of positive column, cathode spot, and anode spot; as a result, melting and evaporation occur in the contact strip, contact wire, and other current collection parts to cause erosion 1,2 . Such erosion contributes to wear of the current collection parts; in the worst case, cracks in the pantograph or breakage of contact wire may occur 3 …”
Section: Introductionmentioning
confidence: 99%
“…This discharge is a hightemperature free arc with complex movement of positive column, cathode spot, and anode spot; as a result, melting and evaporation occur in the contact strip, contact wire, and other current collection parts to cause erosion. 1,2 Such erosion contributes to wear of the current collection parts; in the worst case, cracks in the pantograph or breakage of contact wire may occur. 3 In order to avoid such erosion and breakage, one needs to clarify underlying mechanisms, and research has been conducted toward explanation of physical phenomena that occur before and after disconnection arc.…”
Section: Introductionmentioning
confidence: 99%