Development of the Unified Series-Shunt Compensator for Power Quality Mitigation

Abstract: This study describes the derivation of an analytical model and simulation for the unified series-shunt compensator (USSC) for investigating power quality in power distribution system. The USSC simulation comprises of two 12-pulse inverters which were connected in series and in shunt with the system. A generalized sinusoidal pulse width modulation (SPWM) switching technique was developed in the proposed controller for fast control action of the USSC. Simulations were carried out using the PSCAD/EMTDC electromag… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
13
0

Year Published

2010
2010
2016
2016

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 15 publications
(13 citation statements)
references
References 9 publications
0
13
0
Order By: Relevance
“…(Chen, 2011;Kouzou et al, 2010;Kumkratug, 2010a;Omar et al, 2010;Zhihuan, et al, 2010;Osuwa and Igwiro, 2010). They have proposed many methods to improve stability of power system such as load shedding, High Voltage Direct Current (HVDC), Flexible AC Transmission system (FACTS), etc (Al-Husban, 2009;Barbuy et al, 2009;Hannan et al, 2009;Kumkratug, 2010b;Mohammadi-Ivatloo, 2009;Sahoo, et al, 2010;Zarate-Minano et al, 2010).…”
Section: Introductionmentioning
confidence: 99%
“…(Chen, 2011;Kouzou et al, 2010;Kumkratug, 2010a;Omar et al, 2010;Zhihuan, et al, 2010;Osuwa and Igwiro, 2010). They have proposed many methods to improve stability of power system such as load shedding, High Voltage Direct Current (HVDC), Flexible AC Transmission system (FACTS), etc (Al-Husban, 2009;Barbuy et al, 2009;Hannan et al, 2009;Kumkratug, 2010b;Mohammadi-Ivatloo, 2009;Sahoo, et al, 2010;Zarate-Minano et al, 2010).…”
Section: Introductionmentioning
confidence: 99%
“…It consists of two solid state converters. They are coupled through a common DC link (Hannan et al, 2009;Jiang et al, 2008). To verify the capability of UPFC on transient stability enhancement, its suitable mathematical model and control strategy are needed to be presented.…”
Section: Introductionmentioning
confidence: 99%
“…Flexible AC Transmission System (FACTS) devices have been proposed to improve stability of power system Hassan et al, 2010a;Fernandes et al, 2009;Omar et al, 2010;Osuwa and Igwiro, 2010;Santos et al, 2010). They have proposed many methods to improve stability of power system such as load shedding, High Voltage Direct Current (HVDC), Flexible AC Transmission system (FACTS), (AlHusban, 2009;Hassan et al, 2010b ;Kumkratug, 2010;Meshkatoddini et al, 2009;Hannan et al, 2009;Zarate-Minano et al, 2010).…”
Section: Introductionmentioning
confidence: 99%