2007
DOI: 10.1109/tasc.2007.899698
|View full text |Cite
|
Sign up to set email alerts
|

Development of the Butt Joint for the ITER Central Solenoid

Abstract: Abstract-The ITER Central Solenoid (CS) requires compact and reliable joints for its Cable-in-Conduit Conductor (CICC).The baseline design is a diffusion bonded butt joint. In such a joint the mating cables are compacted to a very low void fraction in a copper sleeve and then heat treated. After the heat treatment the ends are cut, polished and aligned against each other and then diffusion bonded under high compression in a vacuum chamber at 750 C. The jacket is then welded on the conductor to complete the joi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 5 publications
0
4
0
Order By: Relevance
“…This joint is a butt joint, similar to the one used in the CS Model Coil (CSMC) [6], [7]. A special development has been undertaken by the ITER US Domestic Agency, who will be in charge of the procurement of the CS, to demonstrate that this type of joint is matching the operating conditions of a CS module [8], in particular the fatigue constraints. Fig.…”
Section: Jointsmentioning
confidence: 99%
“…This joint is a butt joint, similar to the one used in the CS Model Coil (CSMC) [6], [7]. A special development has been undertaken by the ITER US Domestic Agency, who will be in charge of the procurement of the CS, to demonstrate that this type of joint is matching the operating conditions of a CS module [8], in particular the fatigue constraints. Fig.…”
Section: Jointsmentioning
confidence: 99%
“…Because of its dangerous nature, this transient in CICCs has been deeply investigated both from experimental [114,[119][120][121][122][123][124] and numerical [101,106,110,[125][126][127][128][129][130][131][132][133][134][135] points of view.…”
Section: Introductionmentioning
confidence: 99%
“…The typical features of a quench transient in a CICC, with reference to the data collected during the latest ITER CS Insert (CSI) test campaign in 2015 [114], see Figure 4.38 for the sensors location, are reported here. This case, although quite complex, has been chosen as a reference because the conductor was very well instrumented in terms of TH and electrical measurements:…”
Section: Introductionmentioning
confidence: 99%
“…The CS design originally had a butt joint as the baseline compact joint [1]. A soldered version of a lap joint was dismissed due to doubling of the cooling lines for cooling the joint and significant increase (basically double) of the joint volume.…”
Section: Introductionmentioning
confidence: 99%