1999
DOI: 10.1109/77.783473
|View full text |Cite
|
Sign up to set email alerts
|

Development of superconducting cavities for high intensity proton accelerator at JAERI

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
10
0

Year Published

2005
2005
2011
2011

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 1 publication
1
10
0
Order By: Relevance
“…A number of lower-β elliptical cavity prototypes have now been built by various laboratories [2,3,4,5,6,7,8,9,10]. Moreover, the Spallation Neutron Source (SNS) is using superconducting elliptical cavities with β = 0.61 and β = 0.81 for the SNS linac.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A number of lower-β elliptical cavity prototypes have now been built by various laboratories [2,3,4,5,6,7,8,9,10]. Moreover, the Spallation Neutron Source (SNS) is using superconducting elliptical cavities with β = 0.61 and β = 0.81 for the SNS linac.…”
Section: Introductionmentioning
confidence: 99%
“…Although SNS uses normal conducting cavities for velocities below the reach of the SNS β = 0.61 cavity, single-cell prototypes of elliptical cavities for even lower β values have been prototyped at several laboratories: two β = 0.48 cavities (700 MHz) were tested by Los Alamos [2]; a β = 0.45 cavity (1.3 GHz) was tested by KEK [3]; two β = 0.5 cavities (600 MHz) were tested by JAERI [4]; a β = 0.47 cavity (700 MHz) was tested by INFN-Milano and Saclay [10]. Encouragingly, the desired gradients and quality factors were exceeded in all of these single-cell tests.…”
Section: Introductionmentioning
confidence: 99%
“…The detuning is periodic from pulse to pulse. The amount of the static detuning was in agreement with the simulation [14] within a few percent. The frequency component of the dynamic detuning is mainly 50 Hz and 810 Hz with amplitudes of 4˚ and 8˚, respectively.…”
Section: Linacsupporting
confidence: 73%
“…Though SNS will use normal conducting cavities for velocities below the reach of the SNS 0:61 cavity, single-cell prototypes of elliptical cavities for even lower values have been prototyped at several laboratories: two 0:48 cavities (700 MHz) were tested by Los Alamos [2]; a 0:45 cavity (1.3 GHz) was tested by KEK [3]; two 0:5 cavities (600 MHz) were tested by JAERI [4]; a 0:47 cavity (700 MHz) was tested by INFN-Milano and Saclay [10]. Encouragingly, the desired gradients and quality factors were exceeded in all of these single-cell tests.…”
Section: Introductionmentioning
confidence: 99%
“…A number of lowerelliptical cavity prototypes have now been built in France, Germany, Italy, Japan, and the United States [2][3][4][5][6][7][8][9][10]. Moreover, the Spallation Neutron Source (SNS), presently under construction, adopted superconducting elliptical cavities with 0:61 and 0:81 for the SNS linac.…”
Section: Introductionmentioning
confidence: 99%