2007
DOI: 10.1016/j.colsurfa.2006.12.056
|View full text |Cite
|
Sign up to set email alerts
|

Development of steady state adsorption distribution over interface of a bubble rising in solutions of n-alkanols (C5, C8) and n-alkyltrimethylammonium bromides (C8, C12, C16)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
51
0
7

Year Published

2007
2007
2021
2021

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 71 publications
(62 citation statements)
references
References 33 publications
4
51
0
7
Order By: Relevance
“…With increasing solution concentration the position of the maximum on the local velocity profiles is shifted towards shorter distances, while its height and width are diminishing. Thus, influence of the BSA in solutions of pH = 5.8 was similar to that of typical surfactants (Sam et al 1996;Liao and McLaughlin 2000;Krzan and Malysa 2002;Krzan et al 2004Krzan et al , 2007Malysa et al 2005;. At the highest BSA concentration studied (c = 6 × 10 −7 M) the bubble terminal velocity of ca.…”
Section: Velocity Of the Rising Bubblesmentioning
confidence: 91%
See 4 more Smart Citations
“…With increasing solution concentration the position of the maximum on the local velocity profiles is shifted towards shorter distances, while its height and width are diminishing. Thus, influence of the BSA in solutions of pH = 5.8 was similar to that of typical surfactants (Sam et al 1996;Liao and McLaughlin 2000;Krzan and Malysa 2002;Krzan et al 2004Krzan et al , 2007Malysa et al 2005;. At the highest BSA concentration studied (c = 6 × 10 −7 M) the bubble terminal velocity of ca.…”
Section: Velocity Of the Rising Bubblesmentioning
confidence: 91%
“…Stroboscopic illumination of frequency 100 flashes per second was applied in measurements of the bubble local velocity as a function of distance from the capillary. Details of the set-up and measurement procedures have been described in details elsewhere (Krzan and Malysa 2002;Krzan et al 2004Krzan et al , 2007 Foam stability measurements were carried out using the set-up consisting of: a) cylinder glass column of inner diameter of 45 mm with a fritted glass at the bottom, b) syringe pump for supply fixed amount of gas into the solution. Prior the experiments column was carefully filled with 50 ml of the studied solution in such way that no foam was formed.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations